Product Manual
Table Of Contents
- Powermate PM3800, PM4400E, PM4500 Portable Generator Owner’s Manual
- Table of Contents
- Section 1 Introduction and Safety
- Section 2 General Information and Setup
- Section 3 Operation
- Operation and Use Questions
- Before Starting Engine
- Prepare Generator for Use
- Grounding the Generator When Used as a Portable
- Know Generator Limits
- Transporting/Tipping of the Unit
- Starting Pull Start Engines
- Starting Electric Start Engines (if equipped)
- Low Oil Level Shutdown System
- Charging the Battery (electric start units only)
- Section 4 Maintenance and Troubleshooting
- Part No. A0000024084
- Generador portátil Powermate PM3800, PM4400E, PM4500 Manual del propietario
- Índice
- Sección 1 Introducción y seguridad
- Sección 2 Información general y configuración
- Sección 3 Operación
- Preguntas sobre la operación y el uso
- Antes de arrancar el motor
- Preparación del generador para su uso
- Conexión a tierra del generador cuando se utilice como equipo portátil
- Conozca los límites del generador
- Transporte/inclinación de la unidad
- Arranque de motores de arranque retráctil
- Arranque de motores de arranque eléctrico (si están equipados)
- Sistema de cierre por nivel bajo de aceite
- Carga de la batería (solo unidades de arranque eléctrico)
- Sección 4 Mantenimiento y solución de problemas
- N.° de pieza A0000024084
- Génératrice portable Powermate PM3800, PM4400E, PM4500 Manuel de l’utilisateur
- Table des matières
- Section 1 Introduction et sécurité
- Section 2 Généralités et configuration
- Section 3 Fonctionnement
- Questions concernant le fonctionnement et l’utilisation
- Avant de démarrer le moteur
- Préparer la génératrice à l’utilisation
- Mise à la terre de la génératrice lors d’une utilisation portable
- Connaître les limites de la génératrice
- Transport et inclinaison de la machine
- Démarrer un moteur à lanceur à rappel
- Démarrer un moteur à démarreur électrique (le cas échéant)
- Système d’arrêt en cas de faible niveau d’huile
- Recharger la batterie (machine à démarrage électrique seulement)
- Section 4 Entretien et dépannage
- Réf. A0000024084
Owner’s Manual for Portable Generator 7
Hour Meter
The Hour Meter tracks hours of operation for
scheduled maintenance. See Figure 2-6.
• The CHG OIL display will illuminate every
100 hours. The message will flash one hour
before and one hour after each 100 hour
interval, providing a two hour window to
perform service.
• The SVC display will illuminate every 100
hours. The message will flash one hour
before and one hour after each 200 hour
interval providing a two hour window to per-
form service.
When the hour meter is in flash alert mode,
the maintenance message will alternate with
elapsed time in hours and tenths. The hours
will flash four times, then alternate with the
maintenance message four times until the
meter automatically resets.
• 100 hours - CHG OIL — Oil Change Inter-
val (Every 100 hrs)
• 200 hours - SVC — Service Air Filter
(Every 200 hrs)
NOTE: The hour glass icon will flash when the
engine is running. This signifies the meter is
recording hours of operation.
Figure 2-6. Hour Meter
Connection Plugs
120 VAC, 20 Amp, Duplex
Receptacle (if equipped)
The 120 Volt outlet is overload protected by a
20 Amp push-to-reset circuit breaker. See Fig-
ure 2-7. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater).
Figure 2-7. 120 VAC, 20 Amp, Duplex
Receptacle NEMA 5-20R
120 VAC, 20 Amp, GFCI Duplex
Receptacle (if equipped)
The 120 Volt outlet is overload protected by a
20 Amp push-to-reset circuit breaker. See Fig-
ure 2-8. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater). It also pro-
vides protection with a Ground Fault Circuit
Interrupter with a press to TEST and RESET
button.
Engine Specifications PM3800 PM4500 PM4400E
Displacement 212 cc 224 cc
Spark Plug Part No. 0J00620106
Spark Plug Gap 0.028-0.031 inch or (0.70-0.80 mm)
Gasoline Capacity 18.9 L (5 gal)
Oil Type
See Chart in
Add Engine Oil
Oil Capacity 0.6 L (.63 qt.)
Run Time at 25% / 50% Load 17 / 14 Hours 16 / 12.5 Hours 16 / 13 Hours
* Go to www.powermate.com
or contact an IASD for replacement parts.
Product Specifications