AC/DC Distribution Panel
with Converter & Charger
AC/DC DISTRIBUTION PANEL
with
CONVERTER & CHARGER
PPC models: 35, 45, 55, 75 and 100
Amp with 3 Stage Charging
Installation & Maintenance
SAFETY ALERT
FOR YOUR SAFETY, READ ALL INSTRUCTIONS BEFORE INSTALLATION AND OPERATION.
INSTALLER: Provide these instructions to the end user or consumer.
CONSUMER: Keep these instructions for future reference.
NOTICE: Products are not to be used nor are warranted in aerospace, medical or life safety applications.
WARNING Avoid Personal Injury or Product Damage
NEVER store electrical devices in compartments where flammable liquids (such as gasoline) exist.
DO NOT mount/install unit in compartments designed for storage of batteries of flammable liquids.
1. DISCONNECT RV DC POWER. Disconnect the RV battery POS (+) wire at the battery end before connecting this
Converter/Charger and Distribution Panel to any RVwiring.
2. LOCATION. The mounting location may be on any interior (out of direct weather) surface. Location chosen must be accessible
after installation. When mounted inside a cabinet, the cabinet must be large enough to allow dissipation of heated air. Make
sure that there is a minimum of 1” (one inch) free air space at each end of the unit so that cooling air can move through the unit
properly. AVOID foreign contaminants such as dirt, metal particles or moisture.
3. MOUNTING. Flanges with holes are provided for ease of mounting using standard fasteners. Confirm that the surface that the
Distribution Panel with converter is mounted to is solid and will hold the weight (14 lbs) during vehicle operation.
4. ELECTRICAL REQUIREMENTS. For PPC models, a 120 VAC with 30 Amp source, preferably a separate breaker, is required
to supply power. Electrical consideration should also be given to mounting near the locations of the RV batteries and the 12-
VDC distribution panel.
5. ELECTRICAL CONNECTIONS. Be sure to tighten all connections securely. A loose connection can quickly cause terminals
and wires to overheat.
WARNING Avoid Possible Injury or Death
120 VAC is present. This Converter/Charger is designed to convert 120 VAC to 12 VDC. It also provides low voltage
power for charging on-board 12 VDC batteries. The SRV series Converter/Charger is a switch mode type and is
designed to be maintenance-free with no user serviceable components. The Converter/Charger power output is current
limiting by design.
The Converter/Charger is integrated with a 120 VAC and 12 VDC Distribution Panel that allows easy installation and
centralizes all power connections. Stab type AC breakers with branch circuits are used. The DC fuse block has individually
fused branch circuits. The Converter/Charger can easily be removed without removing the Distribution Panel wiring.