Operation Manual

POW8561 EN
Copyright © 2014 VARO P a g e | 12 www.varo.com
9.3.1 Fitting and changing the saw blade
Caution! Unplug from power source.
Caution! Ensure that the saw housing is well lit.
Remove the two screws of the table insert
Remove the table insert
Use the crank and turn to the left to bring the saw blade as far up as it will go.
Use the wrenches (19-20) to undo the screws on the saw blade (Fig. 8) and exchange the
blade with a suitable replacement. Watch the direction of operation! See the arrow on the
saw blade. The teeth must point towards the on/off switch (1).
9.3.2 Adjusting the cleaving wedge
The gap between the external edge of the saw blade and the cleaving wedge (7) must be
between three and eight millimetres.
Bring saw blade to the 0° position and tighten.
Bring the saw blade into the upper position.
Remove the saw blade protector.
Remove the table surface.
Loosen the screw (A) slightly with a suitable combination wrench until the cleaving wedge
(7) is released (do not remove screw)
Set the cleaving wedge lower or higher by pushing upward or downward in the long hole.
Mount all dismantled parts in reverse sequence.
10 STORAGE, TRANSPORTATION
10.1 Storage
Risk of injury! Store the unit in such a way that it cannot be started by
unauthorised persons. Ensure that no one is able to injury themselves on
the stored unit.
Machine damage! Do not store unprotected in a damp environment.
10.2 Transportation
Note: Only lift the unit using the handles.
Crank the saw blade down as far as it will go.
Parts that extend beyond the saw should be removed.
Transport the unit with the assistance of another person and use the handles.
When dispatching, try to use the original packaging, if possible.