11 TECHNICAL DATA
Rated voltage
230v~
Rated frequency
50 Hz
Power rating:
1000W
Rated current
4.35 A
Max. loading capacity -for single cable
-for double cable
200 kg
400 kg
Cable speed -for single cable
-For double cable
8m/min
4m/min
Hoisting height -for single cable
-For double cable
12 m
6 m
Cable diameter
4,0 mm
Protection rating
IP54
Motor category
M1
Work duty
S3:20%-10min
Protection rating
I
Weight
17 kg
12 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic power level LwA
71 dB(A)
13 PROBLEM-SOLVING
Common Malfunction
Cause
Solution
The opeating switch is
used but the motor
does not turn
1. It is not plugged into the power
supply.
2. The wires are broken or
ripped.
3. Switch Malfunction
4. The capacitor is burned
through.
5. End-switch has not been reset
or a micro switch error
6. The thermal switch has
suffered a wire break.
1. Connect the item to the
power supply.
2. Check the wires and plug
it in again to the outlet.
3. Repair switch or change it
4. Change your capacitor
5. Check the end-switch and
replace the limit switch.
6. Wait until the item cools
down, or replace the thermal
switch.
The operation switch
switch has been
activated. The motor
is very loud, can
however not pick-up
the load.
1. The voltage offered is too
small.
2. The capacitor has become
damaged.
3. The brake is not completely
open.
1. Adjust the work,
depending on the power
supply
2. Change power supply.
3. Allow the machine to be
repaired from a qualified
repair service
After a power loss the
brakes do not hold or
the machine slips
down
The air between the brakes
is too large
The brake spring is ripped.
The brake disk is locked
The brake disk is at the start
already dirty.
Allow the machine to be
repaired from a qualified
repair service.