PROBLEMS
POSSIBLE CAUSES
REMEDIES
Tools will not
run. Air flows
freely from
exhaust
One or more motor
vanes stuck due to
material build up.
Pour air tool lubricating tool into air inlet.
Operate tool in short bursts of forward
and/or reverse rotation where
applicable.
Tap motor housing gently with plastic
mallet.
Disconnect supply. Free motor by
rotating drive shank manually where
applicable
Tool will not
shut off
‘O’ rings throttle valve
dislodged from seat inlet
valve.
Replace ‘O’ ring.