User Manual

POWLI211 EN
Copyright © 2014 VARO P a g e | 2 www.varo.com
The power is to be turned off before mounting the LED floodlight with sensor.
The fitting is to be mounted in such a way that the angle of inclination of the
longitudinal shaft of the lamp (burning position) is less than 4° with respect to the
ground area.
Secure the fitting with two screws or bolts, out of reach and at a minimum height of
2.5m.
The grounding wire (yellow/green) of the connection cable must be connected to the
connection terminal, indicated with grounding symbol. The power wires are to be
fitted in the connection block.
Secure the sealing rubber to guarantee the spatter resistance, and ensure that all
mounting screws are properly fastened.
Installation height of this lamp should be minimum 2.5m.
5 WIRING DIAGRAM (FIG. 2)
Fix the wiring in the connection block according to the included diagram (Fig. 2):
a=brown conductor of the network cable (L)
b=blue conductor power cable (N)
c=yellow/green: grounding cable
d=control (red)
6 USING THE FLOODLIGHT
Simply plug in the cable of the floodlight to the socket.
7 SETTING THE LIGHT SYSTEM (FIG. 3)
7.1 Test mode
Turn the LITE control and the Time control anticlockwise to the edge (the TEST
position).
Set the SENS. Control to its mid-point.
Turn on the wall switch. The floodlight will turn on for about 1 minute to warm up.
Then it turns off.
Walk through the detection area. The floodlight turns on when you move and turns off
when you stop. Wait for the floodlight to turn off before moving again to test the
sensor.
Adjust the motion sensor to cover the desired detection area.
For a smaller coverage area, point the sensor down; for a larger coverage area, point
the sensor up.
7.2 TIME adjustment
The TIME adjustment controls how long the floodlight will stay on after the motion
has been detected.
Turn the TIME control knob clockwise to increase (up to about 12 minutes) how long
the floodlights stay on or anti-clockwise to decrease (down to about 5 seconds) the
time delay.