9 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
9.1 Cleaning
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
Regularly clean the machine housing with a soft cloth, preferably after each use.
Keep the ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
9.2 Lubrication
From time to time, apply a drop of oil to the thread of the lock screw.
10 TECHNICAL DATA
Rated voltage
220-240V
Rated frequency
50Hz
Rated power
1300W
Rotation speed
5500min
-1
Blade diameter
190mm
Cable length
4m
Max cutting capacity 90°
65mm
Max cutting capacity 45°
48mm
Bore size
20mm
Adjustable angle
Yes
Number of teeth
40T
Blade dimensions
190 x 20mm
11 NOISE
Noise emission values measured according to relevant standard. (K=3)
99 dB(A)
112 dB(A)
ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).
aw (Vibration)
2.5 m/s²
K = 1.5 m/s²
12 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).