Operation Manual
POWX0474 EN
Copyright © 2016 VARO P a g e | 8 www.varo.com
10 TROUBLE SHOOTING
Should the machine fail to function correctly, a number of possible causes and the appropriate
solutions are given below:
10.1 Machine fails to operate.
Power turned off.
(Extension) cable damaged.
10.2 The elektromotor hardly reaches maximum speed.
The extension cable is too thin and/or too long.
The mains voltage is lower than 230 V.
10.3 Machine overheats.
Air vents are blocked. Clean them with a dry cloth.
The machine has been overloaded. Use the machine for the purpose it is made for
10.4 Excessive sparking or elektromotor runs irregular.
There’s dirt inside the motor or the carbon brushes are worn.
Replace the carbon brushes or bring the machine to a specialized repair centre.
Repairs and servicing should only be carried out by a qualified technician
or service firm.
11 TECHNICAL DETAILS
Model nr.
POWX0474
Rated voltage AC (Un)
230V
Rated frequency (fn)
50Hz
Rated power (Pn)
1200W
Rotation speed (n)
600 – 3300min
-1
Disc diameter
180mm
Spindle lock
M 14
12 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
86 dB(A)
Acoustic power level LwA
97 dB(A)
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
aw (Vibration):
7.8 m/s²
K = 1.5 m/s²