To start the tool squeeze the on/off switch (8).
To stop the tool , release the on/off switch.
If you press the lock-on button (9) while the on/off switch is depressed, the on/off switch is
kept in the operating position.
To release the on/off switch (8) again, press it briefly to and turn the tool off.
The harder you squeeze the on/off switch (8) the faster the tool will operate.
Use lower speeds for starting.
8.2 Forward/reverse lever
The forward/reverse lever (7) is to determine the direction of rotation of the tool.
To select forward rotation, release the on/off switch and push the forward reverse lever to right
(R) side of the tool. To select reverse, push the lever to left (L) side of the tool.
When changing the position of the lever, be sure the on/off switch is released and the motor is
stationary.
9 TECHNICAL DATA
Model
Voltage
Power Input
No load speed
Impact rates
Shank style
Max. drilling capacity
Concrete
Steel
Wood
Net weight
Insulation class
10 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
91 dB(A)
Acoustic power level LwA
102 dB(A)
ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).
aw (Vibration)
8,7 m/s²
K = 1.5 m/s²
11 MAINTENANCE
Always keep the drill clean.
Do not use corroding agents for cleaning plastic.
Check carbon brushes in the case of excessive sparking.
Keep ventilation channels free.