Operation Manual

POWX1172 EN
Copyright © 2016 VARO NV P a g e | 7 www.varo.com
Do not use the chuck with SDS connector in combination with the
hammer/hammer drill function!
9 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
9.1 Cleaning
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
Regularly clean the machine housing with a soft cloth, preferably after each use.
Keep the ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
10 TECHNICAL DATA
Rated Voltage
220-240 V
Rated Frequency
50 Hz
Rated Power
1250 W
Rotation speed
800 min
-1
Protection class
II
Drill capacity concrete
30 mm
Drill capacity steel
13 mm
Drill capacity wood
40 mm
Impact rate
3900 min
-1
Cable length
3 m + VDE plug
Chuck type
13mm chuck and adapter
11 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
92 dB(A)
Acoustic power level LwA
103 dB(A)
ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).
aw (Vibration)
14,6 m/s²
K = 1,5 m/s²