10 TECHNICAL DATA
Rated Voltage
220-240 V
Rated Frequency
50 Hz
Rated Power
1050 W
Rotation speed
0-480 min
-1
Protection class
II
Drill capacity concrete
38 mm
Drill capacity steel
13 mm
Drill capacity wood
40 mm
Impact rate
0-3780 min
-1
Cable length
3 m + VDE plug
11 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
96 dB(A)
Acoustic power level LwA
107 dB(A)
ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).
aw (Vibration)
14,9 m/s²
K = 1,5 m/s²
12 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).
13 STORAGE
Thoroughly clean the whole machine and its accessories.
Store it out of the reach of children, in a stable and secure position, in a cool and dry
place, avoid too high and too low temperatures.
Protect it from exposure to direct sunlight. Keep it in the dark, if possible.