Phau Ntawv Qhia
POWX11861 EN
Copyright © 2022 VARO P a g e | 9 www.varo.com
▪ To prevent the oil from running out in an uncontrolled manner, hold a small metal chute
under the opening and collect the oil in a vessel until it has fully drained out of the
machine.
Important: The waste oil must be disposed of in the appropriate
collection point for waste oil.
▪ Add new oil (approx. 25 ml) through the oil filler opening until the oil level reaches the
required level. Tighten the hexagonal screw again.
▪ Re-check the oil level after a short period of operation.
10 MAINTENANCE
Check every day the tightening of screws and nuts. Except the procedures described in this
manual, this tool needs no specific maintenance. The repair of the tool's inner components is
of the competence of specialists. The cleaning of plastic parts is done with a soft damp cloth
and a bit of mild soap. Never submerge the tool and do not use detergents, alcohol, spirit,
etc...For an in-depth cleaning, please consult the after-sales department.
WARNING: For maintenance and cleaning, always remove the plug from
the electric power supply. Never use water or other liquids to clean
electric parts.
11 TECHNICAL DATA
Rated voltage – rated frequency
220-230V~ 50Hz
Rated Power
1700W
Protection class
class II
Cable length
5m
Chuck type
SDS Hex
Impact Rate
1900 beats/min
12 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
84 dB(A)
Acoustic power level LwA
105 dB(A)
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
aw (Vibration):
17.8 m/s²
K = 1.5 m/s²
13 SERVICE DEPARTMENT
▪ Damaged switches must be replaced by our after-sales service department.
▪ If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).