Operation Manual

POWX1195 EN
Copyright © 2016 VARO NV P a g e | 9 www.varo.com
11 TECHNICAL DATA
Rated Voltage
230 V
Rated Frequency
50 Hz
Rated Power
1500 W
Rotation speed
860 min
-1
Protection class
II
Drill capacity concrete
32 mm
Drill capacity steel
13 mm
Drill capacity wood
42 mm
Impact rate
4250 min
-1
Cable length
3 m + VDE plug
12 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
93 dB(A)
Acoustic power level LwA
104 dB(A)
ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).
aw (Vibration)
17,4 m/s²
K = 1,5 m/s²
13 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).
14 STORAGE
Thoroughly clean the whole machine and its accessories.
Store it out of the reach of children, in a stable and secure position, in a cool and dry
place, avoid too high and too low temperatures.
Protect it from exposure to direct sunlight. Keep it in the dark, if possible.
Don’t keep it in plastic bags to avoid humidity build-up.