Manual

Parts List
Item Part Number Description
1 450-280 SHROUD (showerhead)
1 450-280A SHROUD (handshower)
2 450-273A SCREW 10-32 UNF x 1/4
3 450-268 SOAP DISH
4 450269G CAP, END CHROME PLATE
5 450-272 SCREW 8-32 X 1-1/4
6 410-017A TRIM PLATE COVER
7 220-054 SLEEVE KIT
8 420-049 HANDLE KIT
9 141-379
SHOWERHEAD - ADJUSTABLE
SWIVEL
10 141-816 SHOWERHEAD - FIXED
11 141-837
PUSHBUTTON SHOWER
HAND SPRAY
12 141-319
IN-LINE VACUUM BREAKER
(handshower)
13 042-672G
NIPPLE - 12" 'NPT X 1-1/8" LG
(handshower)
14 450-277
GASKET - SHOWERHEAD
BASE
15 450-276 SET SCREW 10-32 UNF X 7/8
16 450-267G
BASE, SHOWERHEAD
CHROME PLATE
17 047-013 QUAD RING 3/8" ID X 1/2" OD
3
What to look for if:
1. The fl ow of the water is less then desired.
a. Valves upstream from supply not fully open.
b. Low supply pressure.
c. Accumulation of lime deposit in hot water pipes, restrict-
ing the fl ow of the hot water
d. Showerhead clogged. Remove and clean.
e. Checkstops may not be fully open.
2. Flow of water is completely shut off.
a. Valves upstream from supply completely closed.
b. Failure of hot or cold water supply pressure.
c. Checkstops closed.
3. Flow is untempered hot or cold water.
a. The water supplies are connected to wrong ports.
b. Check for foreign material that may be clogging the car-
tridge.
4. Flow of water continues when valve is shut off.
a. Worn shut off disc. Replace cartridge.
b. Scratched mixing plate. Replace with bonnet/stem kit.
5. Checkstops leak or they won't shut off.
a. The checkstops may be damaged. Replace with check-
stops replacement kit.
6. Maximum temperature is too low.
a. Accumulation of lime deposit in hot water pipes, restrict-
ing the fl ow of the hot water
b. The concealed maximum temperature limit stop is not at
its maximum adjustment. Set the maximum temperature
limit stop.
c. Hot water is too low.
Troubleshooting