User Guide
45
Troubleshooting
!
Always use proper precautions when accessing circuit breaker box.
Problem:
Solution:
Outlet temperature above set point
1. Ensure flow is above the minimum rated flow by opening the hot water valve on two to four fixtures being
supplied with tempered water from the panel.
2. Ensure that the cold supply is flowing.
3. Check cold water temperature and ensure that it is lower than the set point temperature and supply line
has no obstructions or closed valves restricting flow to the IntelliStation.
4. Unlock the control and then select the “Toolbox” to navigate to the “Toolbox” menu. From within the
“Toolbox” menu use down arrow to highlight “Reset” then press enter. This will access “Reset” menu.
Press the “YES” and then press accept. The controller will reset and begin start up sequence.
Note: Alternately, the control can be reset by opening and closing the circuit breaker switch and waiting 100
seconds to resume normal operation.
6. If problem persists after conducting the above outlined problem solving procedures, contact Powers,
Technical Support at 800-669-5430 or info@PowersControls.com.
If screen displays "---" instead of a measured value
1. Sensor is not connected or functioning properly.
2. Check the connection at the sensor and the connection within the control module.
Problem:
Solution:
BEFORE attempting to open Control
Module, a certified and qualified elec-
trician MUST fully de-energize and
disconnect all electrical power from
IntelliStation
®
.
Perform required LOCK OUT/TAG OUT
procedures.
When done, reconnection and reenergiz
-
ing of IntelliStation
®
MUST
be performed
by certified and qualified electrician.
DANGER
!