Product Overview

HYDROGUARD
®
Series LFLM495 Thermostatic
Mixing Valves for Lavatory Installations
ES-P-LFLM495
Product Specification
powerscontrols.com
Union ConneCtions
Female NPT Sweat CPVC PEX Quick-Connect
1/2"
(15)
3/4"
(20)
1"
(25)
1/2"
(15)
3/4"
(20)
1"
(25)
1/2"
(15)
3/4"
(20)
1"
(25)
1/2"
(15)
3/4"
(20)
1"
(25)
1/2"
(15)
3/4"
(20)
1"
(25)
LFLM495-1 LFLM496-1 LFLM497-1 LFLM495-2 LFLM496-2 LFLM497-2 LFLM495-3 LFLM496-3 LFLM497-3 LFLM495-4 LFLM496-4 LFLM497-4 LFLM495-5 LFLM496-5 LFLM497-5
Specifications n
Temperature Adjustment:
80°- 120°F (27°C to 49°C)
Approach Temperature: 5°F (3°C) above set point Check Valves: Integral
Max. Operating Pressure: 125psi (861 kPa) Construction: Lead Free* Cast copper silicon alloy body
Max. Hot Water Temperature: 200°F (93°C) Listing: ASSE 1069, ASSE 1070, ASSE 1017 and
IAPMO cUPC
Max. Pressure Differential
between Hot & Cold Water Supplies: 25%
Minimum Flow: 0.5 gpm (1.90 lpm) when tested in accordance
with ASSE 1069, ASSE 1070 and ASSE1017
Advanced Thermal
Activation
Features n
Temperature control to ASSE 1069, 1070 and 1017 down to 0.5 gpm
Advanced thermal actuator improves performance at low ow
Lead Free* cast copper silicon alloy body construction for durability and to comply
with Lead Free* requirements
Adjustable temperature selection with lock down
Union connections for easy maintenance
Integral checks and screen prevents cross-ow and contamination
Available in
1
/2",
3
/4", 1" (15, 20, 25 mm) with NPT, Sweat, PEX, Quick-Connect, and
CPVC union connections
LEAD FREE
*
Capacity n
PressUre DroP ACross the VAlVe
(C
V
) 1 psi
(7 kPa)
5 psi
(34 kPa)
10 psi
(69 kPa)
15 psi
(103 kPa)
20 psi
(138 kPa)
30 psi
(207 kPa)
45 psi
(310 kPa)
60 psi
(414 kPa)
1.79
4.0 gpm
(15.0 lpm)
5.7 gpm
(22.0 lpm)
7.0 gpm
(26.0 lpm)
8.0 gpm
(30.0 lpm)
9.8 gpm
(37.0 lpm)
12.0 gpm
(45.0 lpm)
13.9 gpm
(53.0 lpm)
*T he wetted surface of this product contacted by consumable
water contains less than 0.25% of lead by weight.
When used in an ASSE 1017 application at the hot water
source, the Powers Thermostatic Mixing Valve Series
LFLM495 cannot be used by itself to control final tem-
perature at fixtures where ASSE Standard 1016 or ASSE
Standard 1070 listed devices are required. Such use may
result in severe bodily injury (i.e. scalding or chilling) and/or
death. ASSE Standard 1016, ASSE 1069 or ASSE Standard
1070 listed devices, such as Powers Series LFe480 or
LFLM495, should be used at point-of-use to prevent pos-
sible injury. Consult all product manuals, and instruction
guides before installing any referenced product.
Recirculation systems should recirculate water at tempera-
tures over 140°F to reduce the risk of bacterial growth in the
piping. This valve should not be used at the hot water source
in recirculation systems.
WARNING
!

Summary of content (2 pages)