Specification

Specifications: PowerStar AE3.4, AE7.2, AE9.5, AE12
NOTE
: The inlet water temperature plus the degree rise from the heater will be the final delivered temperature. Only limited flow
from a hot water outlet, refer to flow/degree rise table below.
Model
Volts
Amps
Element Resistan
ce
Low Setting
AE3.4*
120
-
110
27
2x8Ω
3.4
-
3.0kW
--
AE7.2
240
-
220
30
2x16Ω
7.2
-
6.1kW
--
AE7.2
240
-
220
15
1x12Ω
--
3.6
-
3.05kW
AE9.5
240
40
2x12Ω
9.5kW
--
AE9.5
240
20
1x12Ω
--
4.75kW
AE9.5
208
35
2x12Ω
7.1kW
--
AE9.5
208
18
1x12Ω
--
3.5kW
AE12**
240
50
--
12.0kW
--
Temperature Rise (°F) at Flow Rate (GPM)
Model
.50 GPM
.75 GPM
1.0 GPM
1.5 GPM
2.0 GPM
AE3.4*
41°F
28°F
20°F
n/a
n/a
AE7.2
n/a
63°F
48°F
32°F
24°F
AE7.2
n/a
32°F
24°F
16°F
12°F
AE9.5
n/a
84°F
64°F
42°F
32°F
AE9.5
n/a
42°F
32°F
21°F
16°F
AE9.5
n/a
64°F
48°F
32°F
24°F
AE9.5
n/a
32°F
24°F
16°F
12°F
AE12**
72°F
72°F
72°F
52°F
42°F

Summary of content (1 pages)