ELECTRICAL CONNECTIONS
WARNING
All electrical connections must be performed by a qualified
electrician. Make sure tool is off and disconnected
from power source while motor is mounted, connected,
reconnected or anytime wiring is inspected. Motor
and wires are installed as shown in wiring schematic
(See Figure 14). Motor is assembled with approved,
3-conductor cord to be used at 120 volts.
The power lines are inserted directly into the switch. The
green ground line must remain securely fastened to the
frame to properly protect against electrical shock. The
power supply to the motor is controlled by a single pole
locking rocker switch.
Remove the key to prevent unauthorized use.
TO CONVERT TO 240V POWER SUPPLY
To convert the dust collector to 240V the switch box must
be rewired and a new plug attached. A qualified electrician
MUST inspect the switch box and new plug before the
dust collector is connected to the power source.
The 240V power supply circuit must have a verified
ground and meet these requirements:
Circuit Type ...........240V/240V, 60 Hz, Single Phase
Circuit Size ...............................15 Amps
Plug Receptacle ........................ NEMA 6-15
TO CONVERT
1. Make sure the tool is unplugged.
2. Open the switch box cover.
3. Follow the 240V wiring diagram on the inside of the
switch box cover. NOTE: The 240V wiring diagram
is also in Figure 14. Call the customer service line at
847-780-6120 for assistance if needed.
4. After rewiring make sure all wire nuts are tight and
use electrical tape to secure them in place.
5. Replace the plug on the existing power cord with
a NEMA 6-15 plug. The plug must be plugged into
matching outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
6. Have the wiring inspected by a qualified electrician.
7. Replace the switch box cover.
6
ASSEMBLY
Figure 14