GREEN POWERLINK Smart Energy Monitoring & Surge Protecting Solution R9P014 / R9P125A6Z8 / R9P602NIZ8 User Manual All Versions © Copyright 2012 The information contained herein is subject to change without notice. The information contained herein is subject to change without notice. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent.
TABLE OF CONTENTS INTRODUCTION INTRODUCTION........................................................................... 2 FEATURES AND FUNCTIONS ...................................................... 3 INSTALLATION............................................................................ 8 Wireless Setup Range................................................................... 8 Install Wall Tap Surge Protector................................................... 8 Install Strip Surge Protector ............
FEATURES AND FUNCTIONS R9P014 Smart Energy Monitor Features Top View Front View Back View Radio Frequency 915MHz 915MHz Wireless Range Up to 100 Ft Control Energy Saver Smart Energy Monitor Specification Side View outlets ON/OFF Yes Audible Alarm Alert Yes Functions 1. RESET Key : restore factory default 12. Real Time and accumulative energy 2. LEARNING Key: add new channel usage indicator: the plug icon flashes 3.
R9P125A6Z8 Wall Tap Surge Protector Features R9P602NIZ8 Strip Type Surge Protector Features 1. Surge Protection LED Indicator - The lighted green LED indicates the surge protection is working 2. Manual ON/OFF & LEARNING Key - Manual ON/OFF Mode: press the Manual ON/OFF Key to turn ON/OFF the AC outlet - Learning Mode: press the LEARNING key to pair up the surge protector with the energy monitor 3.
INSTALLATION Strip Type Surge Protector Specification Radio Frequency 915MHz Wireless Range Up to 100 Ft Always On Outlets 2 Energy Saver Outlets 4 AC Rating 15A / 125V / 1875W Surge Suppression Rating 640J Clamping Voltage 400V Surge Protected LED Indicator Green Grounded Fault LED Indicator Red Always On LED Indicator Green External Antenna Yes Manual ON/OFF , LEARNING Key Yes Stand-by Power <1 W Operating Temperature 5℃~45℃ at 85% relative humidity Storage Temperature -5℃~60℃
3. Plug in the AC power cord of the strip surge protector to a powered 125V AC outlet. 4. The “ENERGY SAVER” outlets power can be manually turned ON/OFF by pressing the “Manual ON/OFF” button on the strip surge protector. Use an AC/DC Adapter (Optional) The energy monitor can operate with a 9V AC/DC adapter, which can be purchased separately.
Currency and Electricity Setup The average carbon emission rate is 0.49Kg (1.08 lbs) of carbon emission for event your local utility uses a tariff calculation other than flat electricity rate, every 1 KWH of electricity produced. This can be changed depending upon your please key in the average rate that most nearly resembles your utility’s tariff local electric utility. Please contact your local utility for carbon emission rate. schedule. 1. The Kg symbol blinks first.
Change channel to monitor different surge protectors Turn ON/OFF the energy saver outlets on the surge protector The energy monitor can monitor up to 9 energy tracking surge protectors. Each The energy monitor can display the ON/OFF Status of the energy saver outlets on CH number represents an energy tracking surge protector. the surge protector. Use the arrow key to change the channel from CH1 to CH9 to ALL channels.
View real time and projection energy consumption View Real Time energy information for the channel In Real Time Mode, the energy monitor will display instant energy consumption in Watts, energy cost in $/hr, and carbon emission in Kg/hr. View projection energy information for the channel DAY Month Year The energy monitor provides real time and projection energy information. Press the MODE button to scroll thru different energy information display.
View accumulation energy consumption View total day energy accumulation for the selected channel The energy monitor provides energy usage accumulation display. This allows you to view total accumulation energy usage in day, month and year for each channel. DAY DAY DAY DAY Activate the energy accumulation mode for the selected channel 1. The energy monitor will first display DAY 01 for 3 seconds, then display the total energy accumulation data for 10 seconds in repeat cycle. 2.
View total year energy accumulation for the selected channel Month Surge events counter with sound alert Year 1. When the total energy usage accumulates over 12 months, it will move and store the total energy accumulation data in YEAR database, and the MONTH accumulation data will be reset to 0 from MONTH 00. 2. Press the MODE button to switch and view the total day energy usage accumulation from DAY, MONTH and YEAR.
4. Within 10 seconds, press the LEARNING button on the energy monitor to add energy tracking surge protector to the selected channel. 5. The Surge Protector will beep once to confirm that it has been successfully added to the channel on the energy monitor. 6. Redo step 3~5 if learning is not successful. 7. Repeat step 2~5 to add more energy tracking surge protectors to different channels on the energy monitor.