6.3.6 CONNECTIONS
This section shows the connections to be made and the characteristics of the material to be used.
The MBS Unit is a weather-protected device once the equipment has been installed in its final location; make
sure that there is no MBS Unit connector without plug or cable connected. Besides, the external wiring
connections of the MBS Unit must be protected from weather, (vulcanizable tape can be used if it is
necessary).
To connect two MBS Units you must have the interconnection kit for additional carrier (Cod.
D014001PT). This is obtained as an independent accessory. In the following table is showed the connection
between two MBS Unit using the interconnection kit
Connections
MBS_1 connector
MBS_2 connector
Power Supply
Power_OUT
Power_IN
Ethernet
ETH
ETH
Synchronism
SYNC_OUT
SYNC_IN
Diversity in reception
DIV_OUT
DIV_IN
DIV_IN
DIV_OUT
For MBS units without duplexer (O148051), the following external filter must be installed:
Frequency range
Attenuation in RX relative to
the pass band
Attenuation in TX relative to
the pass band
380 470 MHz
80 dB @ TX band
60 dB @ offset
(1)
> 10 MHz
80 dB @ RX band
60 dB @ offset
(1)
> 10 MHz
763 806 MHz
91.5 dB @ TX band
70 dB @ offset
(1)
> 32 MHz
85 dB @ RX band
70 dB @ offset
(1)
> 32 MHz
806 870 MHz
80 dB @ TX band
60 dB @ offset
(1)
> 20 MHz
80 dB @ RX band
60 dB @ offset
(1)
> 20 MHz
(1)
Frequency offset from the upper and lower edges of the band pass.