6.3.6.1.4.1 CONFIGURATION WITH PBS ACCESSORY
The connections are the following ones:
Power supply for the PBS Accessories 1 and 2: 220/110 VAC or 24 VDC.
From ANT connector of the PBS Accessory 1 to the antenna 1.
From ANT connector of the PBS Accessory 2 to the antenna 2.
Connection with radio link through PoE connector (if the MBS Unit has SNI IP option this
connector is Layer 3).
Maintenance through PoE connector.
Note 1: The connection with the NMS Server-Client Rugged Laptop in the PoE connector depends of the
network topology and just applies in Isolated Operation Mode of the MBS Unit.
Note 2: The use of the PBS accessory for two MBS Units with SNI IP option is not supported.
PBS #1
Power Input
Anten
na 1 (Tx
F1
/Rx1)
Power Input
Radio Link 2
Radio Link 1
Anten
na2 (TX
F2
/Rx1)
TX
F1
: Transmission Output Frequency 1
TX
F2
: Transmission Output Frequency 2
RX1: Reception Chain 1 of Frequency 1 and 2
PBS #2