EN EN Line Interactive UPS PowerWalker VI 450 IEC PowerWalker VI 650 IEC PowerWalker VI 850 IEC PowerWalker VI 1200 IEC PowerWalker VI 2200 IEC Quick Start Guide EN
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS – This manual contains important instructions for models PowerWalker VI 450 IEC / 650 IEC / 850 IEC / 1200 IEC / 2200 IEC that should be followed during installation and maintenance of the UPS and batteries. • This product is specially designed for PCs and it is not recommended for use in any medical equipment, life-supporting system and other specific important equipment.
• The UPS contains one/two large-capacity batteries. So the shell shall not be opened, otherwise such dangers as electric shock will be caused. If any internal overhaul or replacement of the battery is required, please contact the distributor. • Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. • A battery can present a risk of electrical shock and high short circuit current.
1. Introduction PowerWalker VI series is an intelligent and compact line interactive UPS (Uninterruptable Power Supply) which is designed to protect your personal computer or sensitive electronic equipments from all forms of power interference, including complete power failures. It is equipped with many features that allow any attached equipment to operate longer and more reliability. 2.
4.
5. Installation and Initial Startup Before installation, please inspect the unit. Be sure that nothing is damaged. I: Placement & Storage Conditions Install the UPS in a protected area that is free of excessive dust and has adequate air flow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Please place the UPS away from other units at least 20 cm to avoid interference.
III: Connect the Loads Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the power switch of UPS unit, and devices connected to the UPS will be protected by UPS unit. EN Do not attach a power strip or surge suppressor to the UPS. IV: Connect LAN cable, Modem or Phone line for Surge Protection Connect for example a single modem or phone line into surge-protected “IN” outlet on the back panel of the UPS unit.
6. Functions & Operation I: DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged. Just simply press the power switch to turn on the UPS. II: Green Power Function These series are equipped with Green Power Function for saving power and protecting battery. The feature of deep discharge protection is adoped on battery mode.
8. Maintenance I. General The UPS is virtually maintenance free: take care of proper environmental conditions and keep air inletsoutlets free of dust. II. Fuses If the AC input fuse is defect, be sure it is replaced by a compatible fuse from the same make and type. Never short circuit batteries. When working with batteries, remove watches, rings and other metal objects, and only use insulated tools. III. Batteries Read all safety rules before replacing the battery.
. Specifications Model Complete Series VI 450 IEC EN INPUT Voltage Voltage Range OUTPUT Voltage Voltage Regulation Frequency Range Frequency Regulation Transfer Time Waveform PROTECTION Full protection ENVIRONMENT Humidity Noise Level Software Monitoring Software Model CAPACITY BATTERY Type & Number Charging Time Backup Time (est. 100W) PHYSICAL LED Indicator Outlet and Connector Dimension (DxWxH) WEIGHT Net weight Model CAPACITY BATTERY Type & Number Charging Time Protection Backup Time (est.