EN Line Interactive UPS PowerWalker VI 650 LCD/UK PowerWalker VI 850 LCD/UK PowerWalker VI 1000 LCD/UK PowerWalker VI 1500 LCD/UK PowerWalker VI 2000 LCD/UK Quick Start Guide
IMPORTANT SAFETY INSTRUCTIONS EN SAVE THESE INSTRUCTIONS – This manual contains important instructions for models PowerWalker VI 650/850/1000/1500/2000 LCD /UK that should be followed during installation and maintenance of the UPS and batteries. This product is specially designed for PCs and it is not recommended for use in any lifesupporting system and other specific important equipment. This equipment can be operated by any individual with no previous training.
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing batteries, replace with the same type and number of the sealed lead-acid batteries. The maximum ambient temperature rating is 40°C. This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen.
1. Introduction EN PowerWalker VI series is an intelligent and compact line interactive UPS (Uninterruptible Power Supply) which is designed to protect your personal computer or sensitive electronic equipments from all forms of power interference, including complete power failures. It is equipped with many features that allow any attached equipment to operate longer and more reliability. 2.
4.
4. Installation and Initial Startup EN Before installation, please inspect the unit. Be sure that nothing is damaged. I: Placement & Storage Conditions Install the UPS in a protected area that is free of excessive dust and has adequate air flow. Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT operate the UPS where the temperature exceeds 0-40° C and the humidity is over 0-90 % RH. II: Connect to Utility and Charge Plug in the AC input cord to the wall outlet.
NEVER connect a laser printer or scanner to the UPS unit, because in-rush current generated by motor’s devices may cause the damage of the unit. VI: Turn On/Off the Unit Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again the power switch. 6. Audible alarm from the UPS When UPS switches from AC mode to Battery Mode to back up power supply: sounding every 10 seconds When battery is low: sounding every second When UPS is overloaded: sounding every 0.
. Specifications EN Model CAPACITY INPUT Voltage Voltage Range Frequency Range OUTPUT Voltage Regulation Transfer Time Waveform Protection BATTERY Type & Number Charging Time Protection Backup Time (est. 120W) PHYSICAL LCD Indicator Dimension (DxWxH) ENVIRONMENT Humidity Noise Level Model CAPACITY INPUT Voltage Voltage Range Frequency Range OUTPUT Voltage Regulation Frequency Range Transfer Time Waveform BATTERY Type & Number Charging Time Protection Backup Time (est.