User's Manual

G3L-1929- Installation and Service Manual
Section 5. Maintenance
5-1 Introduction
This section contains periodic maintenance and performance test procedures for the G3L-1929-
120 Multi-Carrier Power Amplifier (MCPA).
NOTE
Check your sales order and equipment warranty before attempting to service or re-
pair the unit. Do not break the seals on equipment under warranty or the warranty will
be null and void. Do not return equipment for warranty or repair service until proper
shipping instructions are received from the factory.
5-2 Periodic Maintenance
Periodic maintenance requirements and the intervals at which the tasks should be performed are
listed in table 5-1.
Table 5-1 Periodic Maintenance
Task Interval Action
Inspection:
Cables and Connectors
12 Months Inspect signal and power cables for frayed insulation.
Check RF connectors to ensure that they are tight.
Performance Tests 12 Months Perform annual test per paragraph 5-4.
Clean Fans/Heat Sinks 3 Months
Inspect for debris. Remove dust with a soft cloth/brush
or vacuum cleaner.
5-3 Test Equipment Required For Test
Test equipment required to test the amplifier is listed in table 5-2. Equivalent test equipment may
be substituted for any item, keeping in mind that a thermistor type power meter is required.
NOTE
All RF test equipment required must be calibrated to 0.05 dB resolution. Any devia-
tion from the nominal attenuation must be accounted for and factored into all
output readings.
Table 5-2 Test Equipment Required
Nomenclature Manufacturer Model
Signal Generator H.P. 8656B
20 dB Attenuator, 250 Watt Bird Tenuline
20 dB Attenuator, 20 Watt (2 each) Bird Tenuline
Spectrum Analyzer H.P. 8560E
Coax Directional Coupler H.P. 778D
Power Meter / Sensor H.P. 437B / 8481A
Arbitrary Waveform Generator Sony AWG2021
Network Analyzer H.P. 8753C
Copyright Powerwave Technologies, Inc., May 2003. All rights reserved
044-05138 Rev. A 5-1 May 2003