CONTROLS
Release the pedal handle lightly with your foot (1), pull back the handle (2) to start the motor. The
brushes and the drum starts rotating. Pulling the handle further without pressing the pedal, lowers
the machine and engages the rotating brushes onto the floor. To stop working, take the handle to the
vertical position.
1
2
OFFON
BEFORE
RESET
WAIT
SECONDS
30
!
PRESS
On/Off Control
Pull Cable Connect / Disconnect Control
Insert the free end of solution cable into the valve body fitted in the solution tank. Press and twist clock-
wise to secure the cable end. Similarly, press and twist counter-clockwise to disconnect the cable end.
Important - Should the machine fail to operate, contact the supplier from whom you purchased the machine.
Transport/Working Mode Control
Slide this knob to TOP position (Working Mode) to operate the machine. Slide this knob to BOTTOM
position to move the machine and park the machine.
Warning! Keeping the knob in the top position (working mode) and moving the machine will damage
the brushes.
1
2
OFFON
BEFORE
RESET
WAIT
SECONDS
30
!
PRESS
Brush Contact Control
Brush contact with the floor is adjustable in 4 steps, contact is MINIMUM when the knob is fully down and
MAXIMUM when it is fully raised. This helps you to compensate for the wear of brushes and also to con-
trol the scrubbing effect. If the machine does not move when the handle is lowered, slide the transport/
working mode knob up one step.
1
2
OFFON
BEFORE
RESET
WAIT
SECONDS
30
!
PRESS
Solution Control
By pulling the solution control handle up, the cleaning solution is dispensed on the floor. The solution
stops once the solution control handle is released.
1
2
OFFON
BEFORE
RESET
WAIT
SECONDS
30
!
PRESS
Motor Circuit Breaker
In the event of motor getting overloaded due to improper power supply or unexpected obstruction to
the brush/drum rotation, the circuit breaker trips and protects the motor from damage. If this happens,
identify the cause, correct it and, reset the breaker after minimum of 30 seconds from tripping by
pressing the circuit breaker button manually and continue working.