Section 4 - Operation Instructions 
Note:  The lamps in the heater module will respond very quickly when turned on, but the most 
effective drying results will occur after the heater module has been on for about 45 to 60 
seconds. This allows the heater module enough time to start producing hot air. 
Once the Dry-IR Drying System has been properly installed, it is very easy to operate. When 
used with an interlock to the transport, it will operate only when the transport is running. 
ON/OFF Switch
Turning the ON/OFF switch to ON will apply power to the heater module and blower. 
Note:  The heater module must be in the drying position, the interlock circuit must be 
energized to allow the on/off switch to apply power to heater module. 
Process Controller 
The keys on the face of the unit operate the process controller. Additional information on 
operating the controller can be found in the Watlow users Manual. 
Manual Mode (Open Loop Control) 
Manual mode on the process controller is indicated by the % indicator being lit. The 
Auto/Manual mode can be toggled by pressing the advance key until A-M appears in the right 
(green) window and pressing the up/down keys to toggle control. 