Section Three - Preventive Maintenance
Preventive maintenance measures are either scheduled (performed on a regular basis by the
owner) or unscheduled (performed when you make a service call). Maintenance performed by
the owner is limited to cleaning and visually inspecting the climber and making the adjustments
specified in the C760 Series Owner's Manual. Scheduled preventive maintenance activities are
included here so that you are aware of preventive measures performed on a regular basis.
Regular Preventive Maintenance (Owner)
Cleanliness of the C760 Series Climbers and their operating environment will keep maintenance
problems and service calls to a minimum. For this reason, Precor recommends that the following
preventive maintenance schedule be followed.
At the End of Each Day
Wipe down the stair arms and frame with a damp cloth.
Every Week
Wipe the surface of the electronic console with a barely-damp sponge or soft cloth. Dry with
a clean towel.
Vacuum underneath the climber, following these steps:
a. Turn off the climber with the circuit breaker, then unplug the power cord from the wall
outlet.
b. Place the climber on one side (either side will do).
c. Vacuum the rug or “damp mop” the floor.
d. Make sure that the floor is dry before returning the climber to an upright position.
On-Site Preventive Maintenance (Service Technician)
Perform the following preventive maintenance tasks each time you are called to service a C760
Series Climber:
Examine the belts, sheave, disk, and bearings for wear, cracks, or other signs of
deterioration and replace if necessary.
Visually inspect the power cable harness. Replace the power cable harness if it is torn or
damaged.