Service manual
C762, C764, C764i Stairclimber
Page 21
along the adjustment slots, the assembly must stay in place after it is moved.
6. Slide the top part of the magnet assembly along its adjustment slot until the .050 feeler
gauge fits snugly between the disk and the top coil on the assembly.
7. Place the .050 feeler gauge between the disk and the lower coil on the right magnet
assembly. Choose one:
IF... THEN...
The .050 feeler gauge does not fit snugly Continue with Step 9
The .050 feeler gauge does fit snugly and Skip to Step 10
you have loosened the magnet
assembly
The .050 feeler gauge does fit snugly and Skip to Step 11
you have not loosened the magnet
assembly
8. Slide the lower part of the magnet assembly along its adjustment slot until the .050 feeler
gauge fits snugly between the disk and the lower coil on the assembly.
9. Tighten the bolts, lock washers, and flat washers that secure the right magnet assembly to
the climber frame.
10. Repeat Steps 3 through 8 for the left magnet assembly, if it has not already been checked.
11. Lift the stairarm assembly from the frame weldment. Grasp the stairarm belt and lift it over
the toothed pulley. Route the belt under the belt idler.
12. Check the operation of the climber as described in Section Four, then replace the covers as
described in Procedure 7.1.