Service manual
C762, C764, C764i Stairclimber
Page 42
Replacing the Upper PCA
9. Carefully connect the keypads to the upper PCA.
10. Position the upper PCA over the plastic mounting tabs on the display housing.
11. Push the upper PCA onto the plastic mounting tabs. Press down the upper PCA until the
edge of the PCA is held by the tabs.
12. Connect the upper ribbon cable to the upper PCA.
13. Remove the ground lead of the wrist strap from the climber frame, then remove the wrist
strap from your arm.
14. Line up the tabs on the display housing with the holes on the display base plate.
15. Gently press the display housing onto the base plate until the tabs are pushed into the
holes.
16. Replace the screws that secure the display housing to the display base plate.
17. Check the operation of the climber as described in Section Four, Checking Unit Operation.
Diagram 7.2 - Removing the Upper PCA