Procedure 7.12 - Replacing the Magnet Cable Assembly
Removing the Magnet Cable Assembly
1. Remove the right cover as described in Procedure 7.1.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
2. Remove the screw that secures the magnet cable in the cable clamp.
3. Remove the magnet cable assembly from the lower PCA.
4. Remove the blue, red, and yellow wires from the four magnet coils.
Replacing the Magnet Cable Assembly
The wires that make up the magnet cable assembly are pre-formed. When the magnet cable
assembly is installed correctly, the wires will fit naturally around the magnet assemblies.
5. Push the blue wire connectors on the magnet cable assembly onto the top terminals on the
upper magnet coils (see Diagram 7.7).
6. Push the red wire connectors on the magnet cable assembly onto the top terminals on the
lower magnet coils.
7. Connect one yellow wire to the empty terminals on the magnet coils of the right magnet
assembly. Connect the remaining yellow wire to the empty terminals on the magnet coils of
the left magnet assembly.
8. Connect the magnet cable assembly to the lower PCA.
9. Place the magnet cable in the cable clamp you opened in Step 2. Install the screw that
secures the magnet cable in the cable clamp.
10. Check the operation of the climber as described in Section Four, then replace the cover as
described in Procedure 7.1.