Procedure 2.1 - Determining Software Version and Total
Floors Climbed
Software version numbers are invaluable for tracking and identifying problems and staying aware
of changes to the operation and features of the product. Units manufactured after May 28, 2000
(software version 6.20) Utilize standard access codes. See Diagrams 2.1 and 2.2 for key number
assignments.
Procedure
1. Plug the power cord into the wall outlet, then turn on the climber with the ON/OFF switch.
2. On units manufactured prior to May 29, 2000, at the PRESS ENTER FOR PROGRAMS
prompt, press the WORK LEVEL ▲ and WORK LEVEL ▼ keys simultaneously. The C762
display is shown in Diagram 2.1 and the C764 display is shown in Diagram 2.2
3. On units manufactured after May 28, 2000, press keys RESET, 6,5, sequentially. The C762
display is shown in Diagram 2.1 and the C764 display is shown in Diagram 2.2
4. The version number of the PROM is displayed in the upper right alpha-numeric display.
5. Press and release the ENTER key. The total number of floors is displayed in the upper right
alpha-numeric display.
6. Press the RESET or ENTER key to return to the PRESS ENTER FOR PROGRAMS
prompt.
Note:
If you cannot determine the software version number in this manner, look at the PROM (U8)
mounted on the upper PCA. A label on U8 indicates the software version number.