Product Owner's Manual C952i C954i C956i C966i Commercial Treadmills C966i
Important Safety Instructions When using the treadmill, always take basic precautions, including the following: • Before beginning any fitness program, make sure all users see a physician for a complete physical examination. Il est conseillé de subir un examen médical complet avant d’entreprendre tout programme d’exercise. Si vous avez des étourdissements ou des faiblesses, arrêtez les exercices immédiatement.
• Never block the air vents while operating the treadmill. Keep the air vents clean and free of lint, hair, or anything that might impede the free flow of air. • Never drop or insert objects into any opening. Keep hands away from moving parts. • Keep all electrical components, such as the power cord and I/O switch away from liquids to prevent shock. Do not set anything on the handrails, display console, or covers. Place liquids, magazines, and books in the appropriate receptacles.
Canadian Department of Communications Le présent appareil numérique n’émet pas de bruits radioéélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministére des Communications du Canada.
Grounding Instructions DANGER Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the unit is properly grounded. Do not modify the plug provided with the treadmill. If it does not fit the outlet, get a proper outlet installed by a qualified electrician. The treadmill must be connected to a dedicated, grounded circuit. A 20 amp dedicated circuit is recommended.
Password Security Security Clip The security clip must be attached at waist level before a user begins exercising on the treadmill. A lanyard connects the security clip to the red STOP button on the display console. If a user encounters difficulties, a strong tug on the lanyard stops the running belt. Obtaining Service You should not attempt to service the treadmill except for maintenance tasks described in this manual. For information about product operation or service, see the Precor website at www.
Table of Contents Important Safety Instructions ...............................................1 Treadmill Weight Limit ................................................................... 2 Treadmill Location .......................................................................... 2 Safety Approval ............................................................................... 2 Radio Frequency Interference (RFI) ........................................... 2 Canadian Department of Communications .........
Treadmill Safety Features The treadmill is equipped with certain items that, when used properly, help sustain an enjoyable workout. These items include: Security clip • Security clip • Password protection • Handrails • I/O power switch Important: Before allowing users on the treadmill, review the Important Safety Instructions found at the beginning of this manual. You should also teach users how to safely use the treadmill following the guidelines in Educating Users.
Important: If QUICKSTART is pressed, the running belt begins moving after a 3-second countdown. Tell users to hold onto the handrail with one hand before pressing the QUICKSTART key with the other hand. CAUTION: Do not assume the treadmill is safe because of password protection. Never leave children unsupervised around the treadmill.
Club Features These next few pages explain how to customize the treadmill for your club. All these features remain hidden to the club patrons and can only be accessed using special key presses. Read this section if you want to: • Change the display to a different language • Change the display to U.S.
Choosing a Language (C952i) The treadmill can display user prompts, text, and user entries in six different languages. When the treadmill is shipped from the factory it is set to display English. Note: Programming prompts are not affected by language selection. The prompts in this section continue to appear in English. To change the language setting, perform the following steps: 1.
Selecting a U.S. Standard or Metric Display The treadmill can display measurements in either METRIC or U.S. STANDARD. The default factory setting is set to display U.S. STANDARD. To change this setting, perform the following steps: 4. At the SELECT UNITS prompt, use an arrow key to select a unit of measure (U.S. STANDARD or METRIC). CAUTION: If you change the Unit of Measure display, be sure to check the speed setting to verify that it is correct. 5.
Determining the Club Speed Limit Setting a Workout Time Limit You can set a maximum speed for the treadmill. This limits how fast the running belt moves and, consequently, how many adjustments a user can make to the treadmill’s speed. The speed is displayed in miles per hour (mph) or kilometers per hour (kph) depending upon the units of measure (U.S. standard or Metric) selected earlier. The range of speeds available are: You can limit how long a user can exercise on the treadmill.
Setting a Pause Time Limit Setting a Cool-Down Time Limit You can limit how long a user can pause while exercising on the treadmill by entering a time between 1 and 120 seconds (two minutes). For example, if you set the pause time limit to 60 seconds, the display automatically resets to the Precor banner if no key press occurs within one minute. You can limit how long a user cools down after exercising on the treadmill by entering a time between 1 and 5 minutes. 12.
Enabling or Disabling the Fitness Test Informational Displays (C952i) The Fitness Test is disabled at the factory. When the Fitness Test is disabled, it is not available in the list of programs. If you wish to add the option to the user’s choice of programs on the treadmill, you need to enable the Fitness Test. The treadmill provides information about its use (odometer and hour meter), as well as software version, and error log.
Viewing the Hour Meter HOURS appears on the display followed by the number of hours that the unit has been in use. The treadmill tracks the elapsed minutes, but the value that appears is truncated to the nearest full hour. 3. When you are ready, press SELECT to move to the next display (software version). Viewing the Software Version and Part Numbers UPPER SW scrolls across the display followed by the upper board application software part number and version (for example, 48181-350). 4.
C952i Entertainment Power Connection The entertainment power port on the C952i treadmill provides a power-only connection. It cannot handle CSAFE protocols. You may use the port to connect to entertainment products. Contact Precor Customer Support for compatibility information. Refer to Obtaining Service. Informational Displays (C954i, C956i, C966i) The treadmill provides information about its use (odometer and hour meter), as well as software version, error log, and serial number.
Viewing the Error Log ERROR LOG appears on the display followed by the first entry in the error log if there are any errors. Up to ten error codes can be retrieved. If there are no errors in the log, you will see NO MORE ERRORS displayed. 7. To view any additional error codes in the error log, use the arrow keys. Each error code specifies when it occurred, listing the odometer and hour meter values. Refer to Diagram 8.
Displaying the Serial Number SER NUMB (C954i) or SERIAL NUMBER (C956i and C966i) appears on the display followed by the 13-digit serial number. The serial number is helpful when you contact Customer Support. Keypad Description SPEED ▼ or ▲ moves the blinking LED from field to field INCLINE ▲ or ▼ changes the number value in the selected field Number keypad use the number keys to enter a user ID. The number that is pressed appears in the display and the next field begins to blink.
Maintenance It is important to perform the minor maintenance tasks described below. Failure to maintain the treadmill as described in this section could void the Precor Limited Warranty. DANGER To reduce the risk of electrical shock, always unplug the unit from its power source before cleaning it or performing any maintenance tasks. Inspection Inspect the treadmill daily. 1.
Storing the Chest Strap If you purchased the optional heart rate chest strap, store it in a place where it remains free of dust and dirt (for example, in a closet or drawer). Be sure to protect the chest strap from extremes in temperature. Do not store it in a place that may be exposed to temperatures below 32° F (0° C). To clean the chest strap, use a sponge or soft cloth dampened in mild soap and water. Dry the surface thoroughly with a clean towel.
Adjusting the Running Belt If you are unsure about adjusting the running belt, call Precor Customer Support (see Obtaining Service). CAUTION: To ensure your safety, use the I/O power switch to turn OFF the treadmill before making any adjustments. Do not adjust the running belt when someone is standing on the unit. 1. Locate the right belt adjustment bolt in the rear end cap of the treadmill. Refer to Diagram 9.
Troubleshooting Error Codes If any error codes appear in the display, call an authorized service person for assistance. Refer to Obtaining Service. Troubleshooting Heart Rate Note: To conduct electrical impulses from a user’s heart, both touch-sensitive handrail grips must be grasped firmly for five to ten seconds. Usually, the concentration of salts in a person’s perspiration provides enough conductivity to transmit a signal to the receiver in the display console.
Precor Commercial Equipment Limited Warranty PLEASE READ THESE WARRANTY TERMS AND CONDITIONS CAREFULLY BEFORE USING YOUR PRECOR INCORPORATED PRODUCT. BY USING THE EQUIPMENT, YOU ARE CONSENTING TO BE BOUND BY THE FOLLOWING WARRANTY TERMS AND CONDITIONS. Limited Warranty. Precor Incorporated warrants all new Precor products to be free from defects in materials and manufacture for the warranty periods set forth below. The warranty periods commence on the invoice date of the original purchase.
This Limited Warranty shall not apply to: 1. Software (PROM) version upgrades. 2. Normal wear and tear, consumables and cosmetic items, including, but not limited to the following: grips, seats, and labels. 3. Repairs performed on Precor equipment missing a serial number or with a serial tag that has been altered or defaced. 4. Service calls to correct installation of the equipment or instruct owners on how to use the equipment. 5. Pickup and delivery involved with repairs. 6.
Thank You and Welcome to Precor We are confident that you will be pleased with your purchase and that your new Precor equipment will help satisfy your customers’ fitness needs, while helping you meet your business goals. To allow us to serve you better, please take a few moments to complete and return your warranty registration. YOU MAY ALSO REGISTER ONLINE AT www.precor.
TELL US ABOUT YOUR NEW PRECOR PRODUCTS Purchased from (Dealer name): Date of Purchase: Month Year Day Product Serial Number(s): Please indicate the type and number of products purchased: ❑ #: ______ Elliptical Fitness CrossTrainer (EFX®) The serial number is located on the shipping box and on the product. ❑ #: ______ Treadmill ❑ #: ______ Stair Climber ❑ #: ______ Cycle ❑ #: ______ Strength Station ❑ #: ______ StretchTrainerTM Add additional sheets of paper or register online at www.precor.
C952i/C954i/C956i/C966i Commercial Treadmills Programs Product Specifications C952i/C954i 86 in (218 cm) 37 in (93 cm) with handrails Length Width Height Weight Shipping weight Running surface Motor Power Speed Incline Frame Regulatory Approvals C956i 86 in (218 cm) 37 in (93 cm) with handrails C966i 86 in (218 cm) 37 in (93 cm) with handrails 34 in (86 cm) without handrails 55 in (140 cm) 55 in (140 cm) 59 in (150 cm) 365 lb (166 kg) 365 lb (166 kg) 375 lb (170 kg) 460 lb (209 kg) 460 lb (209 kg) 470
User's Reference Manual C952i Commercial Treadmill
Important Safety Instructions When using the treadmill, always take basic precautions, including the following: Read all instructions before using the treadmill. These instructions are written to ensure your safety and to protect the unit. • Before beginning any fitness program, see your physician for a complete physical examination. Il est conseillé de subir un examen médical complet avant d’entreprendre tout programme d’exercise.
Password Security Obtaining Service The club owner or facility manager can help you with most questions regarding the treadmill. For additional information about product operation or exercise routines, see the Precor website at www.precor.com. User’s Reference Manual: Important Safety Instructions IMPORTANT SAFETY INSTRUCTIONS The club or facility you are using has the option to enable password protection. The password involves entering three keys in sequence.
Table of Contents Important Safety Instructions ...............................................1 Password Security ......................................................................... 2 Obtaining Service ........................................................................... 2 Treadmill Safety Features ......................................................4 Safety Considerations ................................................................... 4 Using the Security Clip ...........................
Treadmill Safety Features The treadmill is equipped with certain items that, when used properly, help sustain an enjoyable workout. These items include: • Security clip • Password protection • Handrails • I/O power switch Using the Security Clip Attach the security clip to your clothing before each workout. A tug on the lanyard trips the security switch inside the display console and stops the running belt.
Entering the Password Turning the Unit ON and OFF The club or facility has the option to enable password protection. If the password prompt PW appears, press the following key sequence: To turn the unit ON and OFF, use the I/O power switch located at the front of the unit, near the power cord. Refer to Diagram 2. INCLINE ▼, SPEED ▼, SPEED ▲. An asterisk appears on the display with each key press.
Heart Rate Features Heart Rate Target Zones 114 200 190 180 170 Your Heart Rate Heart rate and SmartRate® features are available when you wear a chest strap. When a heartbeat is detected, a number (representing your heart rate) appears in the display when the HEART RATE LED is lit. The SmartRate LED pulses and indicates your target zone. The chest strap is an optional purchase item for the C952i treadmill. Check with the club or facility manager to see if a chest strap is available.
• After you put on the chest strap, face the display console for a minimum of 15 seconds. This allows the receiver in the console to recognize the signal from the chest strap. • If three dashes (— — —) appear on the display, the treadmill cannot detect a heart rate. Make sure the chest strap is positioned properly around your chest and against your skin. • Always face forward on the treadmill and use the handrail for balance.
Exercise to Your Target Heart Rate Whether you use the Manual (MANL) or Interval (INTV) Programs, you can exercise to your target heart rate by wearing the chest strap. As you exercise, your actual heart rate appears in the display when the HEART RATE LED is lit. The SmartRate LED pulses and indicates your target zone. For more information about exercise routines, refer to the Precor web site at www.precor.com.
Display Console Center display: When you begin a program, the program profile displays and remains until the scanning process is initiated. SmartRate display: LEDs light in this column when the SmartRate feature is activated. Follow the LEDs to monitor your heart rate and maintain it in your target zone. C952i SmartRate Above Cardiovascular Weight Loss Below LEDs: Light and clarify what workout statistics appear on the display.
The center display shows the following information. This information is shown in alphabetic order. CALORIES—displays the estimated cumulative number of calories burned. The calorie calculation is derived from the speed, incline, and your weight. An accurate weight entry results in a more accurate calorie count. When using QUICKSTART and a weight has not been specified, the default weight is 150 pounds (68 kilograms). DISTANCE—shows a linear distance in either miles or kilometers.
Keypad Use the keypad to enter your workout session selections. Keys on the keypad respond to the slightest touch. Use gentle pressure on the keys as you exercise. The incline setting affects the column height in the program profile as shown in Diagram 4. The height of the column indicates the level of incline. Every time the incline changes by four sequential levels (up or down) the height of the column changes by one row. The top row lights when inclines are 12% or above.
STOP: A firm tap on the red STOP button slows the running belt to a stop and the treadmill enters pause mode. To resume, press the SPEED ▲ key and, if necessary, enter the password. Refer to Pausing During a Workout or the Cool-Down Period. SELECT: The SELECT key has two functions: • To select a program • To change features displayed during a workout; refer to Changing the Display Features Using the SELECT Key.
Workout Options CAUTION: Before beginning any fitness program, see your physician for a complete physical examination. Know your physician-recommended heart rate target zone. 1. Turn the unit ON. The Precor banner scrolls across the display. C952i SmartRate PRECOR Above Cardiovascular 6. Select one of the following options: Option... Steps... To start exercising immediately • Use the QUICKSTART key. • Refer to Choosing QUICKSTART. To select a program and • Use the SELECT key.
Choosing QUICKSTART 3. A 3-second countdown appears on the display, and then the running belt starts moving. 4. Step on to the running belt with the speed at or below 1 mph (1 kph) and begin your workout. Use the SPEED ▲ to increase the speed of the running belt. 1. Press QUICKSTART while the banner is scrolling to bypass the setup prompts and access the Manual Program.
Selecting a Program 5. A workout time blinks in the display. The display indicates the club limit or the default time of 30 minutes. Press the arrow keys to select a workout time (between 1 and 99 minutes) and then press SELECT. Note: If the club allows it, you can select an unlimited workout time by choosing NO LIMIT and then pressing SELECT. 6. Select your weight (1–999) and then your age (1–99). 1. At the scrolling Precor banner, press SELECT. 2.
Cooling Down After a Workout Incorporate a cool-down period into your workout to help lower your heart rate and minimize muscle stiffness or soreness. When you complete a program with a time limit, you automatically enter a cool-down period. The Manual Program profile appears in the display, the running belt speed is reduced by 20%, and the incline is set to 0%. To adjust the speed or incline, press the arrow keys. To stop the running belt or prematurely end a workout session, do the following: 1.
Pausing During a Workout or the Cool-Down Period Press the red STOP button to pause anytime during a workout or during a cool-down period. The pause mode is limited to the club setting (two minutes or less). If you do not resume exercising during that time, the display returns to the banner. 1. To pause, press the red STOP button. 2. To resume exercising from pause mode, press SPEED ▲. 3.
Programs Choosing a Program PROGRAMS To start a new program, press STOP and then press RESET. Manual Interval Fitness Test (if enabled) CAUTION To avoid injury, keep hands and clothing clear from belt and rear roller while operating. Do not stand on the belt when starting. Do not allow children and people unfamiliar with operation on or near this treadmill. Security lanyard clip must be clipped to user. Do not attempt to turn around on the moving belt. Read owner's manual before operation.
Program Tips • • Work out indefinitely in any program (except Fitness Test). At the time prompt, specify NOLIM. While you exercise, TIME indicates the amount of time you have been exercising. If you chose this option, the automatic cool-down period is eliminated. You will need to incorporate a cool-down period by accessing the Manual Program. Place a time limit on any program during the setup phase. At the time prompt, specify the time duration for your workout.
Interval (INTV) Program C952i Fitness (FIT) Test C952i SmartRate SmartRate INTV Above Cardiovascular Weight Loss Below The Interval Program is among the best for conditioning your cardiovascular system. Each 1-minute interval raises and lowers your level of exertion repeatedly throughout the duration of the program. When you begin the program, the incline and speed settings are preprogrammed. To change the settings, press the appropriate arrow key and continue.
The club or facility has the option to make the Fitness Test available to its patrons. If you do not see it as part of your program selection, ask the facility manager. Using the Fitness Test Follow these steps to use the Fitness Test. 1. Buckle the heart rate strap around your chest. Guidelines Before selecting the Fitness Test, read the following guidelines: 2. Grasp a handrail while you step on to the treadmill and straddle the running belt. • 3. Press SELECT at the scrolling Precor banner.
Completing the Fitness Test When you finish the Fitness Test, a 1-minute cool-down period is provided to help return your heart rate to a normal, restful state. You can extend the cool-down period by pressing QUICKSTART at the scrolling banner. The Fitness Test automatically ends if one of the following occurs: • • • • You press the red STOP button. Your heart rate increases and remains above 85% of the maximum allowable heart rate (220 minus your age) for 15 seconds.
Precor, C, CrossRamp, EFX, M, Move Beyond, and SmartRate are registered trademarks of Precor Incorporated. Crosstrainer, QuickStart, and StretchTrainer are trademarks of Precor Incorporated. Copyright 2005 Precor Incorporated. Specifications subject to change without notice. www.precor.com NOTICE: Precor Incorporated 20031 142nd Ave NE P.O. Box 7202 Woodinville, WA USA 98072-4002 Precor is widely recognized for its innovative, award winning designs of exercise equipment. Precor aggressively seeks U.S.
Assembly Guide C966i C952i C954i C956i C966i Commercial Treadmills
Thank you for choosing Precor. For proper installation, please read this guide thoroughly and follow the assembly instructions. If you do not assemble the treadmill according to these guidelines, you could void the Precor Limited Warranty. Installation Requirements Follow these installation requirements when assembling the unit: • Assemble the unit near the location where you plan to use it. • Provide ample space around the unit.
Hardware Kit (not shown to scale) Fasteners Commercial Treadmill Assembly Guide Quantity (A) Buttonhead screw (1-inch) 12 (B) Washer (stainless steel) 16 (C) Socket head screw (3¹⁄₂-inch) 4 (D) Flat head hex screw (1-inch) 4 (E) Washer (stainless steel) 4 2
4 — Barrel spacers (F) 1 — ⁵⁄₁₆-inch hex key (H) 6 — Power cord clips (G) 1 — ¹⁄₄-inch hex key (J) 1 — ³⁄₁₆-inch hex key (K) 1 — ⁵⁄₃₂-inch hex key (L) Commercial Treadmill Assembly Guide 3
Assembly Steps Remove the hood and set it aside. Remove any tape or wire ties that secure the display cable. Unwrap the cable and remove the kinks. Ask your assistant to hold the display console in place while you attach it to the left upright support using two buttonhead screws (A) and two washers (B). Use a ¼-inch hex key and ½-inch box end wrench to remove the four shipping fasteners on the front panel. Discard the nuts, but keep the screws.
Place the right side upright support near the base frame side bracket. Feed the display cable through the upright support. Note: If you encounter difficulties feeding the cable, tie a string to the cable connector and the other end to a washer. Feed the washer through the upright support and pull it and the cable connector out of the base hole. Remove the string. Pull the cable through the side bracket hole in the base frame, and then connect the cable to its receptacle on the lower board near the motor.
Important: Attach the handrails to one side at a time. Attach the upper handrails to the display console extensions using four flat head screws (D). Finger tighten. Important: For easier installation, you can place the side rails or rear feet on blocks. Ask for help when lifting the treadmill. Do not place blocks beneath the running bed. Align the lower handrail bracket with the base mounts. Secure the base of the handrails using four screws (A) and four washers (B). Wrench tighten.
Test the heart rate touch-sensitive grips on the C954i, C956i, or C966i. a. Turn the unit ON. The Precor banner appears in the display. b. Face the display and straddle the running belt. c. Grasp both touch-sensitive handrail grips. d. Look at the Heart Rate display. The letters Hr should be blinking. After a few seconds, a number appears indicating your heart rate. Note: If the display remains blank, turn the unit OFF and recheck the cable connection on the lower board.
Attach the power cord clips. a. Wrap the clip around the power cord near its receptacle and clamp it shut. c. Place the clips, as needed, along the length of the power cord while you redirect it to the power outlet. The holes, found in the frame beneath the side rail, are spaced one foot (31 cm) along the length of the side rail. Power cord clip b. Insert the serrated portion of the clip into the hole located under the front panel.
Level the unit, if needed. Before allowing users on the unit, make sure it is level. Important: If the load is not equally compensated, the user will feel excessive vibration or movement at the display console, Adjust one rear foot at a time. Do not raise the unit beyond 2 centimeters (³⁄₄-inch). Bubble level 3. Ask a capable assistant to use the hand holds on the rear end caps and lift the treadmill (using proper lifting techniques). 4.
Checking the Alignment of the Running Belt Proper belt alignment allows the belt to remain centered and ensures smooth operation. Realigning the belt takes a few simple adjustments. If you are unsure about this procedure, call Precor Customer Support. Refer to Obtaining Service. CAUTION: Special care must be taken when aligning the running belt. Turn OFF the treadmill while adjusting or working near the rear roller. Remove any loose clothing and tie back your hair.
Precor Incorporated 20031 142nd Avenue NE P.O. Box 7202 Woodinville, WA USA 98072-4002 ©2005 Precor Incorporated www.precor.