Users Manual Part 2

Factory Reset
The DataHub can be returned to its original factory defaults (i.e. the way you originally received
it) by one of two methods.
Software
If you are able to WiFi or Ethernet connect to the unit and can login to the web admin ui then
browse to “Services->Settings” and select the “Firmware” tab. Push the “PERFORM RESET”
button to restore the factory default settings.
Note that it takes 5-10 minutes for the process to complete. Do not interrupt the DataHub
during the reset process.
Hardware Reset Switch
A hardware reset is in order if you have either lost the WIFi password or admin password, or are
unable to otherwise access the web admin ui for the DataHub.
To perform a hardware reset locate the rest button next to the power inlet for the unit. You will
find it through a small pin hole through the enclosure. Use a paperclip or other other small
object to depress the button for 15 seconds while the unit is powered on. After 15 seconds
release the button. The unit will then perform a factory reset. Note that a quick push of the
button will reboot the unit but not reset it to its defaults. The button must be held for more than
10 seconds and less than 30 for the reset action to occur.
Legal
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.