INSTALLATION MANUAL CTM-MS3 Flat Panel Display Mount (55” to 63”) NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada – Phone: 800-368-9700 Fax: 800-832-4888 Other Locations – Phone: (001)-714-632-7100; Fax: (001)-714-632-1044 ©Premier Mounts 2009 9531-000-321-03 EUROPE Swallow House, Shilton Industrial Estate, Shilton, Coventry, England CV79JY Phone: +44 (0) 2476 614700 Fax: +44 (0) 2476 614710
CTM-MS3 Table of Contents Warning Statements ........................................................................................................................................- 2 Parts List ...........................................................................................................................................................- 3 Installation Tools .........................................................................................................................................
CTM-MS3 Parts List This wall mount is shipped with all proper installation hardware and components. Make sure that none of these parts are missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop the installation and contact Premier Mounts (800-368-9700).
CTM-MS3 M5 x 25 (Qty 8) M8 x 20 (Qty 8) M5 x 30 (Qty 8) M8 x 25 (Qty 8) M6 x 20 (Qty 8) M8 x 30 (Qty 8) M6 x 25 (Qty 8) M8 x 35 (Qty 8) M6 x 30 (Qty 10) M8 x 70 (Qty 4) M6 x 35 (Qty 8) Page - 4 - Installation Manual
CTM-MS3 Nylon spacers and flat washers actual size NOTE: The nylon spacers may be staked to achieve proper spacing.
CTM-MS3 Thread Depth Indicator 1. 2. 3. 4. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel to make sure the inserts measure the same full depth and mark it. Locate the correct diameter screw for the thread insert. Compare your marking to the screws (supplied). If your selected screw is longer than the marking on the thread depth indicator, DO NOT USE this screw. The screw length must not bypass the marking.
CTM-MS3 Mounting Bracket Installation Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could result in serious personal injury and possible damage to the flat panel. Invert the flat panel place it on a soft, flat surface to prevent damage to the flat panel. Use a blanket, foam, etc. Failure to do so will result in damaging the flat panel. Do not lay the flat panel on the floor without any protection to the glass.
CTM-MS3 Nylon Spacers, If Applicable Center Mark Mounting Brackets Inverted Flat Panel Bottom of Flat Panel Arrows Facing Out Step 3. Install the nylon spacers (if needed) to the mounting points on the flat panel. Step 4. Lay the left and right mounting brackets (stamped arrows facing out). Mounting Bracket CL Bottom of Flat Panel Center of Viewing Guide Align the Mounting Brackets Bottom of the Flat Panel Step 5. Match the center of viewing guide with the centerline you marked in Step 1.
CTM-MS3 Securing the Mounting Brackets Dimples The Griplate™ have M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires. M8 M6 M5 M4 EXAMPLE: If your plasma uses M8 x 20 Phillip screws, use the M8 mounting points. Phillips Head Screwdriver The upper Griplate™ must be mounted with the dimples facing up. The lower Griplate™must be mounted with the flat side facing up. DIMPLES FACING UP Do not over tighten the mounting hardware.
CTM-MS3 CTM-MS3 Installation Mark the wall and the center of the wood studs. CENTER OF VIEWING HEIGHT DESIRED Wood Stud Finder (Commercially available) Measure and mark the viewing height desired on the wall. Wood studs behind the wall structure. Step 1. Using a (commercially available) wood stud finder, locate the 16" or 24" stud centers behind the wall. Step 2. Once found, make a pencil marking on the center of the wood studs. Step 3.
CTM-MS3 Mark the nine (9) mounting slot openings Wall Plate Step 6. Secure the plate using the nine (9) 5/16" lag bolts and flat washers.
CTM-MS3 Installing the Flat Panel Display AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL. Wall Plate Top Bottom Step 1. Raise the flat panel with the mounting brackets secured to the flat panel and insert the top hooks over the upper rod. The lower hooks should rest on the lower rod.
CTM-MS3 Lateral Shift Wall Plate Step 2. Make any lateral shift adjustment and lock it by tightening the two (2) M6 x 30mm Phillips screws found on the bottom of the mounting brackets. Use the foot leveler to adjust your plasma. Do not over tighten the M6 x 30mm screws to the rods. To remove the display from the wall simply back off the M6 x 30mm screws using a Phillips screwdriver and lift the unit of the wall carefully.
CTM-MS3 Step 3. Tilt the flat panel and secure the two (2) M6 x 12mm safety knobs to each of the mounting brackets To remove the display from the wall simply extend the display to its maximum tilt range, remove the two 6 (mm) safety knurl knobs push the flat panel back to it’s flat position, loosen or remove the two (2) M6 x 30 lateral shift screws and lift the unit of the wall.
CTM-MS3 Technical Specifications Figure 18 Installation Manual Page 15
CTM-MS3 Warranty PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of the original owner of this product. The limited warranty is valid only for the original purchaser of the product. What Premier Mounts Will Do At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that is defective.