Check air pressure when tank is empty of water!
Check air pressure in the tank when you notice a decrease in
available water from the RO system.
It is recommended that you drain the tank of water, and then
pump up the RO tank in order to ensure all water is out of the
tank. Air can be added with a bicycle pump.
Once all water in the tank is purged out, check air pressure of the
tank. If you added air to the tank, it will be higher than 5 - 7 psi.
Allow air out until you have 5 - 7 psi in the tank.
Check Air Pressure in the Tank
Step 1
Note:
Step 2
Procedure extended for Non-Use
If the system will not be used for an extended period (more than 2
months), shut the system down and remove the membrane. Place
the membrane in a sealed plastic bag with a few drops of RO water
and place in your refrigerator.