Use and Care Guide

CONVERTING RANGE FROM PROPANE GAS TO
NATURAL GAS
STEP 4 METHOD A or B Convert Oven
Burner:
The oven burner orifice is located beneath
the inlet to the oven burner at the lower rear
portion of the broiler section. ( See Fig. 7)
Using a 1/2” wrench turn the orifice hood
clockwise until it is snug.
Warning: Do not over-tighten the orifice
hood.
PIN
LP GAS
NATURAL GAS
ORIFICE HOOD
Fig. 7
ADJUST AIR SHUTTERS, IF NECESSARY
OVEN BURNER:
The air shutter adjustment for the oven burner is located at
the open end of the oven burner venture tube and sits on the
hood of the oven burner valve. To adjust air shutter:
1. Loosen the screw on the air shutter.
2. Move the air shutter closed to decrease or open to in-
crease the amount of air to the flame.
3. When the flame is properly adjusted, tighten the screw.
SCREW AIR SHUTTER
NO YELLOW TIPS
NO LIFTING
OVEN BURNER
The burner flame should
be a steady blue. A burner
with a yellow flame, un-
steady flame, or a partial
flame is in need of an air
shutter adjustment.
TOP BURNER
NO YELLOW TIPS
26