Use and Care Guide

INSTALLATION INSTRUCTIONS
ADJUST AIR SHUTTERS, IF NECESSARY
TOP BURNERS:
The air shutter adjustment for each top burner is located at the
Open end of the top burner venturi tube and rests on the orifice
hood of the top burner valve. Should the air shutter need ad-
justing, slide the air shutter to allow more or less air into the
burner flame as needed.
OVEN BURNER:
The air shutter adjustment for the oven burner is located at
the open end of the oven burner venturi tube and sits on the
hood of the oven burner valve. To adjust air shutter:
1. Loosen the screw on the air shutter.
2. Move the air shutter closed to decrease or open to in-
crease the amount of air to the flame.
3. When the flame is properly adjusted, tighten the screw.
SCREW
AIR SHUTTER
NO YELLOW TIPS
NO LIFTING
OVEN BURNER
The burner flame should
be a steady blue. A burner
with a yellow flame, un-
steady flame, or a partial
flame is in need of an air
shutter adjustment.
28
TOP BURNER
NO YELLOW TIPS
AIR SHUTTER