Use and Care Guide

CONVERTING RANGE FROM NATURAL GAS
TO L.P. (PROPANE) GAS
STEP 2 METHOD A or METHOD B Convert Range Top Burners:
1. Each top burner must be adjusted to the LP (Propane) setting. With a 1/2” open end wrench rotate the
orifice hood counter-clockwise until it is snug on the valve. The orifice hood is the brass hood on the end of
top burner valve.
ORIFICE HOOD
TOP BURNER
Warning: Do not over-
tighten orifice hood onto
top burner valve.
Fig. 3
2. Repeat this procedure for each of the remaining top burner valves.
STEP 3 METHOD A Convert the Range Oven thermostat.
The oven thermostat control is at the center front of the
range located behind the oven control knob and control panel.
Locate the brass LP (propane) gas conversion screw on the
right side of the oven thermostat as shown in Fig. 4
This screw can be accessed through a hole in the control
panel.
1. Turn the conversion screw clockwise until seated tight into
the oven thermostat control.
2. After the conversion screw has been converted, the oven
pilot flame must be adjusted. In order to properly set the
pilot it is necessary to remove the oven bottom (See page
11 for the oven bottom removal).
GAS CONVERSION SCREW
OVEN THERMOSTAT CONTROL
(located behind the oven control knob and
control panel)
Fig. 5
23
3. Remove the oven burner baffle by removing the wing nut
that holds the baffle to the oven burner. With the baffle
removed, the oven pilot can be observed on the right rear
side of the oven burner.
4. Before adjusting the oven pilot, the pilot has to be lit.
In order to light the oven pilot, rotate the control knob
to the “PILOT” or “LITE” position and push and hold
in on the knob. Hold knob for approximately 10 sec.
before releasing it. The pilot should remain lit. Repeat
step 4 if pilot goes out.
PILOT ADJUSTMENT SCREW
OVEN THERMOSTAT CONTROL
(located behind the oven control knob and
control panel)