Use and Care Manual

Caution for safety
1. Range of workable voltage: 98-133V. In order to avoid damaging the
electrical performance of the compressor, please equip with a power
regulated appliance, with the power not less than 500w, when the voltage is
lower than 98V or higher then 133V.
2. Individual single-phase socket must be used. It should be reliably
connected to be a grounding wire. Caution: The grounding wire is not
allowed to connect to a water pipe or a gas pipe.
3. Strong base, strong acid, organic solvent and corrosive goods or those are
easy to pollute to food are prohibited storing in the showcase, otherwise, it
can cause corrosiveness or accident
4. Don't raise the showcase or the shell of the electric parts, or it will cause
the decline in insulation and the corrosiveness.
5. When the showcase will be out of use for a long time, disconnect the
power first, and then clean it. Please examine the circuit. Whether it is ok
before reuse.
Caution for using
1. Unpack all packages before using the showcase don't topple it over more
then 60°while moving it.
2. The showcase should be installed in the environment of good ventilation.
Cool and dry and without corrosive gas, it should not be installed close to
heat sources or directly under the sunlight. The space more than 10cm,