Operation Manual

35
23) PTT
Transmission key, press to transmit a message, “TX” is displayed and release
to listen to an incoming communication.
A) DC-POWER TERMINAL (13,2 V)
B) ANTENNA CONNECTOR (SO-239)
C) EXTERNAL SPEAKER JACK (8 Ω, Ø 3,5 mm)
D) JACK FOR OPTIONAL PA (Public Address) (Ø 3.5 mm)
E) JACK FOR OPTIONAL VOX MIKE (Ø 2.5 mm)
F) JACK FOR CW DEVICE (Ø 3.5 mm)
G) USB DATA (PC setting in option)
C) MENU FUNCTIONS
Press the MENU key (4) for 2 seconds to enter in the menu function setting.
“FUNC” appears on the LCD.
Use s/t keys (10) to select the desired function.
Use rotary PUSH knob (6) to set the function.
Press any key except PUSH knob (6) or wait for 5 seconds to store and exit.
FUNC disappears from the LCD.
1) ROGER BEEP FREQUENCY
Set the FREQUENCY of the ROGER BEEP.
At [ ] menu, rotate PUSH knob (6) to set the Frequency.
Frequency range: 300 Hz ~ 3000 Hz, stepping frequency:10 Hz, default:1050 Hz.
Press PUSH knob (6) to change the step.
2) ROGER BEEP TIME
Set the TIME (ms) of the ROGER BEEP.
At [ ] menu, rotate PUSH knob (6) to set the delay Time.
Time range 50 ~ 1000 ms, time stepping: 50 ms, default: 500 ms. Press PUSH knob
(6) to change the step.
3) CW FREQUENCY
Set the FREQUENCY of the CW.
At [ ] menu, rotate PUSH knob (6) to set the Frequency.
Frequency range: 300 Hz ~ 3000 Hz, stepping frequency:10 Hz, default:1050 Hz.
Press PUSH knob (6) to change the step.
4) CALL FREQUENCY
Set the FREQUENCY of the CALL tone.
At [
] menu, rotate PUSH knob (6) to set the Frequency.
Frequency range: 300 Hz ~ 3000 Hz, stepping frequency:10 Hz, default:1050 Hz.
Press PUSH knob (6) to change the stepping.
5) MONITOR GAIN VOLUME
Set the OUTPUT VOLUME LEVEL of the microphone in your own speaker.
At [ ] menu, rotate PUSH knob (6) to set the Monitor volume level.
There are 32 levels. “OFF” disable the function.
6) TOT (Time Out Timer)
Set the TOT. If the PTT pedal (23) is pressed for more than “TOT” time, the
transmission ends.
At [ ] menu, rotate PUSH knob (6) to set the TOT, disable the func-
tion. Time range 30 ~ 600 s, time stepping: 30 s, default: 180 s.
7) SWR PROTECTION
Enable/disable the SWR PROTECTION.
At [ ] menu, rotate PUSH knob (6) to enable or disable the
protection. Default: .
8) SWR PROTECTION SETTING
Set the SWR LEVEL PROTECTION.
At [
] menu, rotate PUSH knob (6) to set the protection Level.
Level range:
12 ~ 200 , stepping:1, default: 200. Press PUSH knob (6) to change
the step. The SWR level is useful only in the SWR protection function is active.
9) VOLTAGE PROTECTION
Enable/disable VOLTAGE PROTECTION.
At [ ] menu, rotate PUSH knob (6) to enable or disable
the protection. Default: .
10) VOLTAGE PROTECTION HIGH
Set the HIGHER LIMIT of VOLTAGE PROTECTION.
At [ ] menu, rotate PUSH knob (6) to set the High limit.
Voltage range: 90U ~ 170U V, stepping: 01U, default: 170U. Press PUSH knob (6)
to change the step. The HIGH limit is useful only if the VOLTAGE protection
function is active.
11) VOLTAGE PROTECTION LOW
Set the LOWER LIMIT of VOLTAGE PROTECTION.
At [ ] menu, rotate PUSH knob (6) to set the Low limit.
Voltage range: 90U ~ 170U V, stepping: 01U, default: 90U. Press PUSH knob (6)
to change the step. The LOW limit is useful only if the VOLTAGE protection
function is active.