Ventilation Inserts & Liners Use & Care Manual Intended for Residential Cooking Only READ AND SAVE THESE INSTRUCTIONS Models covered by these instructions: UIB, UIBTF, CMUIB, UIM Installer: Leave this manual with homeowner. Homeowner: Use and Care information inside. Prestige America Ltd. 25 Riverside Dr.
-Table of Contents Important Safety Instructions.........................................................................1-2 Handling Precautions.........................................................................................2 Important Ventilation Information Before You Begin......................................2 Accessories Sold Separately.............................................................................3 Cleaning and Maintenance........................................................
-Important Safety InstructionsPRESTIGE® INSERTS ARE FOR RESIDENTIAL USE ONLY! CAUTION: FOR GENERAL VENTILATION USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS. 1. Use this unit only in the manner intended by the manufacturer. (If you have questions, contact Prestige® at 800-358-8886.) 2. Before servicing or cleaning this unit, switch power off at service panel and lock the panel to prevent power from being switched on by accident.
-Important Safety InstructionsWARNING - IN THE EVENT OF RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: 1. Smother the flames with a close fitting lid, cooking sheet or other metal tray, and then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN. 3. MAKE SURE YOUR VENTILATION SYSTEM IS COMPLETELY TURNED OFF. DO NOT TURN HOOD ON TO TRY AND EVACUATE SMOKE. 4.
- Handling Precautions • Remove all rings, watches, belt buckles, jewelry and any clothing with metal buttons or snaps to prevent damage to the Insert. • DO NOT REMOVE INSERT FROM ITS ORIGINAL CARTON UNTIL YOU ARE READY TO INSTALL IT. • When you are ready to begin the installation process, remove the insert from its carton and place it on a clean soft blanket. • Inspect the insert carefully for any damage or imperfections before you begin to install the insert.
-Important Ventilation Information Before You BeginThe desired installation height of the insert is at the discretion of the user, however, a height of 30" to 36" above the cooking surface is recommended. Two persons are required to install insert. Before installing your insert, be sure to read the following! Prestige® inserts are designed to utilize internal, in-line, or remote blowers. Other blowers CANNOT be substituted. Select the series best suited for your application.
-Cleaning and MaintenanceBe sure lights are cool before cleaning your insert. Your insert will not function properly if not cleaned regularly and maintained properly. Clean the filters regularly (at least twice a month or every 24 hours of use) by soaking them in soapy water and rinsing them in the dishwasher at the normal cycle. When the filters are removed the accessible interior can be cleaned of grease, again using only soap and water.
-Accessories Sold Separately• In-line blowers IL600, IL1200 and IL1600 • Remote blowers, RB1000, RB1200, RB1600, RB2000 • Transitions TR6x15/8, TR6x15/10 (for use with 1200 blower system), TRC8/6 transition collar (for use with 600 blower) • Wall Caps, WC6HD, WC8HD, WC10HD. The WC6x15/HD is for use with the 1200 blower system when rear ducting. • Roof Caps RC6 and RC10 will accommodate 6" to 10" round duct sizes. • Backdraft damper BD8 or BD10 (in-line 8" or 10" section duct with backdraft damper installed.
-Packing List for UIB InsertUIB20-600, UIB26-600 UIB30-600 UIB28-600 Blower Pre-Installed in Unit One (1) Stainless Steel Baffle Filter Two (2) Pre-Installed Lights Lid for Electrical Box UIB34-600 Blower Pre-Installed in Unit Two (2) Stainless Steel Baffle Filters Two (2) Pre-Installed Lights Lid for Electrical Box UIB34-1200, UIB40-1200 Two (2) Blowers Pre-Installed in Unit Two (2) Stainless Steel Baffle Filters Two (2) Pre-Installed Lights Lid for Electrical Box Transition required and NOT supplied (sold
-Packing List for UIB Hood LinerUIB28-NB One (1) Stainless Steel Baffle Filters Two (2) Pre-Installed Lights Lid for Electrical Box Starter Collar Included UIB34-NB, UIB40-NB Two (2) Stainless Steel Baffle Filters Two (2) Pre-Installed Lights Lid for Electrical Box Starter Collar Included UIB46-NB, UIB52-NB, UIB58-NB Three (3) Stainless Steel Baffle Filters Three (3) Pre-Installed Lights Lid for Electrical Box Starter Collar Included UIB58-NB includes two (2) Filter Spacers 8
-Packing List for UIBTF or CMUIBTF Hood LinerUIBTF34-NB, UIBTF40-NB Four (4) Stainless Steel Baffle Filters Two (2) Pre-Installed Lights Lid for Electrical Box UIBTF48-NB, UIBTF58-NB Six (6) Stainless Steel Baffle Filters Three (3) Pre-Installed Lights Lid for Electrical Box UIBTF580WC15 includes two (2) Filter Spacers CMUIBTF34-NB, CMUIBTF40-NB Four (4) Stainless Steel Baffle Filters Two (2) Pre-Installed Lights Lid for Electrical Box CMUIBTF48-NB, CMUIBTF58-NB Six (6) Stainless Steel Baffle Filters Three
-Rear Ducting InstructionsIn some cases, you will not be able to duct the unit to the top. In that case, rear ducting is necessary. 1) Lay insert on its face on top of a soft, non-abrasive blanket. 2) Remove the screws from the L-bracket on the blower assembly. DO NOT LOSE SCREWS. 3) Disconnect motor wires from terminal block. 4) Flip the unit so the exit hole is facing the back of the unit. 5) Re-apply the screws to the L-bracket on the blower assembly.
-Installation GuideNOTE: During installation, protect countertop and/or cooking appliances. 1) Choose an installation height that is comfortable for the user. IMPORTANT: Most building codes require a 30" minimum clearance from the top of a surface burner to the underside of any combustible material. 2) Choose the appropriate cutout dimension from the cutout dimension section (page 13).
-Cutout DimensionsUse the below dimensions to make the cutout for your Prestige® Model# UIB28-600 UIB34-600 UIB34-1200 UIB40-1200 UIB46-1200 UIB52-1200 UIB58-1200 UIB28-NB UIB34-NB UIB40-NB UIB46-NB UIB52-NB UIB58-NB UIBTF34 UIBTF40 UIBTF46 UIBTF52 UIBTF58 CMUIBTF34 CMUIBTF40 CMUIBTF46 CMUIBTF52 CMUIBTF58 Width 25 1/8" 31 1/8" 31 1/8" 37 1/8" 44 5/8" 50 5/8" 56 5/8" 25 1/8" 31 1/8" 37 1/8" 44 5/8" 50 5/8" 56 5/8" 32 3/4" 38 3/4" 44 3/4" 50 3/4" 56 3/4" 32 3/4" 38 3/4" 44 3/4" 50 3/4" 56 3/4" Depth 13 5/8"
-Installation of In-Line or Remote blowerUsing the harness supplied with your Prestige® in-line or remote blower, plug into connector located near insert finger guard. Make all connections between supplied harness and wiring connected to the blower using wire nuts (not included) inside of insert electrical box. -Hood Operating InstructionsThe blower should be turned on for about 5 minutes BEFORE cooking in order to establish air currents upward through the insert.
Warranty Information Prestige® will warranty all parts and related labor to replace them for a term of one (1) year. The one (1) year warranty period applies to the actual parts and NORMAL labor and excludes all other costs, removal and re-installation. One-year service repair warranty: During the first year from date of original purchase, Prestige® will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.