- Handling Precautions -
Remove all rings, watches, belt buckles, jewelry and any clothing with metal buttons or
snaps to prevent damage to the Insert.
DO NOT REMOVE INSERT FROM ITS ORIGINAL CARTON UNTIL YOU ARE READY
TO INSTALL IT.
When you are ready to begin the installation process, remove the insert from its carton
and place it on a clean soft blanket.
Inspect the insert carefully for any damage or imperfections before you begin to install
the insert. If any damage or imperfections exist, re-carton the insert and call your dealer
IMMEDIATELY, do not install a damaged hood.
It is highly recommended that rubber gloves be used to prevent scratches on the insert
and to provide you with a firm grip.
When removing the insert from the carton locate the filters. The filters are not
pre-installed in the insert. The filters are in a box marked filters, inside the insert
carton.
Internal blower inserts can be ducted to the top or the rear. Check product guide for
additional transitions, wall caps and roof caps.
Duct size for units ending in 600 is 6" round and an optional transition model TRC8/6
should be used to increase the duct size to 8" round for optimal performance.
Units with model numbers ending in 1200 require the use of transition model TR6x15/10
(NOT INCLUDED AND SOLD SEPERATELY).
All Prestige® ventilation inserts have a variable speed blower switch as well as a light
dimmer switch.
Inserts can be set up for ductless applications. See product guide for optional
ductless conversion kits.