Technical data
PREXISO P80 788508
8
EN
Technical Data
* maximum deviation occurs under unfavourable
conditions such as bright sunlight or when measuring
to poorly reflecting or very rough surfaces. Measuring
accuracy between 10 m and 30 m may deteriorate to
approx. ±0.15 mm/m, for distances above 30 m to
±0.2 mm/m.
Message Codes
If the message Error does not disappear
after switching on the device repeatedly,
contact the dealer.
If the message InFo appears with a
number, press the Clear button and
observe the following instructions:
Care
• Clean the device with a damp, soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning agents
or solvents.
Disposal
CAUTION
Flat batteries must not be disposed of with
household waste. Care for the environ-
ment and take them to the collection points
provided in accordance with national or
local regulations.
The product must not be disposed with
household waste.
Dispose of the product appropri-
ately in accordance with the
national regulations in force in your
country.
Adhere to the national and country specific
regulations.
Product specific treatment and waste
management can be downloaded from our
homepage.
Warranty
The device comes with a 1-year warranty.
For further information contact your dealer.
General
Range 0.05 to 80 m
0.16 to 262 ft
Measuring accuracy* typ.: ± 1.5 mm
± 0.06 in
Smallest unit displayed 1 mm
1/16 in
Laser class 2
Laser type 635 nm, < 1 mW
Protection class IP54 (dust- and
splash water
protected)
Autom. power switch-off after 180 s
Permanent measuring yes
Addition/Subtraction yes
Dimension (H x D x W) 117 x 57 x 32 mm
4.6 x 2.4 x 1.3 in
Battery durability (2 x AAA) up to 3000 measure-
ments
Weight
(without batteries)
105 g / 3.38 oz
Temperature range:
-Storage
-Operation
-25 to 70 °C
-13 to 158 °F
0 to 40 °C
32 to 104 °F
No. Cause Correction
204 Calculation error Perform measure-
ment again.
252 Temperature too high Let device cool
down.
253 Temperature too low Warm device up.
255 Received signal too
weak, measuring time
too long
Change target
surface (e.g. white
paper).
256 Received signal too
high
Change target
surface (e.g. white
paper).
257 Too much background
light
Shadow target area.
258 Measurement outside
of measuring range
Correct range.
260 Laser beam inter-
rupted
Repeat measure-
ment.