SOFTWARE VERSION 2.1 WWW.PRG.
AutoPar®, Bad Boy®, PRG Series 400®, Mbox Extreme®, V676®, Virtuoso®, Virtuoso® DX, Virtuoso® DX2, and VL6C+™ are trademarks of Production Resource Group, LLC, registered in the U.S. and other countries. All other brand names which may be mentioned in this manual are trademarks or registered trademarks of their respective companies. This manual is for informational use only and is subject to change without notice. Please check www.prg.com for the latest version.
FOREWORD Compliance Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation.
WARNING: INSTRUCTIONS FOR PROTECTION AGAINST INJURY TO PERSONS 1) Exterior surfaces of the luminaire will be hot during operation. Use appropriate safety equipment (gloves, eye protection, etc.) when handling and adjusting hot equipment and components. Service and maintenance should be performed only by qualified personnel as determined by the high pressure lighting fixture manufacturer. 2) Arc lamps generate intense heat. Disconnect power and allow lamp to cool for 15 minutes before relamping.
Notes de sécurité Avant de procéder à l’installation des produits décrits dans ce guide et de les mettre en marche, il est extrêmement important de lire TOUS les renseignements et TOUTES les directives de sécurité contenues dans ce guide ainsi que toute documentation jointe. Tenir compte de tous les avertissements et suivre toutes les précautions pendant l’installation et l’utilisation de cet appareil.
Revision History This manual has been revised as follows: IV Version Release Date BASIC February 8, 2006 Software version 1.0. Initial release. A March 20, 2006 Revised “Aligning Lamp” p. 13 B September 11, 2007 C November 8, 2010 AUTOPAR® WASH LUMINAIRE USER MANUAL Notes Updated menu system operation to software version 2.0 Changed software version to 2.1 and updated book format. (No change to technical information.
TABLE OF CONTENTS Introduction About This Manual........................................................................................................................................................................ 1 Additional Documentation ............................................................................................................................................................ 1 Customer Service ............................................................................................
Appendix A. Technical Specifications AutoPar Wash Luminaire ............................................................................................................................................................
INTRODUCTION About This Manual This manual provides necessary information regarding product safety, installation, and operation for the following PRG equipment: + AutoPar® Wash Luminaire (20.9802.0001) The instructions apply to AutoPar software version 2.1. Familiarizing yourself with this information will help you get the most out of your PRG product.
Customer Service For technical assistance, contact the PRG International Service Center or contact your nearest PRG office. Contact information for all PRG office locations can be found on our website at: www.prg.com/about-us/locations/ PRG Dallas (International Service) 8617 Ambassador Row, Suite 120 Dallas, Texas 75247 USA Phone: 214.630.1963 Fax: 214.630.5867 Service Fax: 214.638.2125 Service Email: orders@prg.com For additional resources and documentation, please visit our website at: www.prg.
1. DESCRIPTION This chapter contains descriptions of luminaire features, components, and accessories.
FEATURES Overview The AutoPar Wash Luminaire from PRG Lighting is a compact, lightweight fixture which incorporates PAR 56 illumination with the dynamic features of an automated luminaire. The AutoPar luminaire features a powerful 700 watt arc lamp, an integrated ballast with power factor correction and a moving yoke. Four interchangeable front lenses provide a wide range of beam options, while a standard gel frame allows for color customization.
COMPONENTS Included Items The following illustration shows all items included with the luminaire: Mega Claw Hook (2) Very Narrow Spot Lens AutoPar Luminaire Clamp Mount (2) Narrow Spot Lens Flex Top Lock Nut (2) 8-Row Lenticular Lens Power Cable Safety Cable 12-Row Lenticular Lens Figure 1-1: AutoPar Wash Luminaire Included Items Replacement Items and Accessories The following items can be ordered from PRG. (Please order by PRG part number.) PRG P/N Accessory 10.9802.0010 Clamp Mount 23.9623.
Major Components and Controls The following illustration shows the external luminaire components and controls. Mega-Claw Truss Hook (2) Allows luminaire to be mounted on truss pipe. (May be replaced with other truss hook types.) Clamp Mount (2) Provides attachment point for truss hooks or other mounting hardware. Upper Enclosure Houses power supply, ballast, and provides Data In and Thru, and AC power connections (see detail below).
2. INSTALLATION This chapter contains instructions for installing the luminaire. It includes connecting power and data, along with instructions for powering up the luminaire for the first time and addressing it within your system.
POWER AND DATA CABLING REQUIREMENTS Power The AutoPar Wash Luminaire requires standard AC power distribution from 100-240 VAC, 50/60 Hz, 10 Amps maximum. The upper enclosure provides a Neutrik® connector for power input. (Power cable not supplied.) Neutrik AC Power Connector Figure 2-1: Power Input Connector Data The AutoPar Luminaire is equipped with two, 5-pin XLR connectors for DATA IN and DATA THRU (out) applications.
The XLR 5-pin connectors should be wired as follows: Pin/Wire Code to XLR Connectors Data Thru Cable Pinout 1 5 2 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Foil & Braided Shield 1st conductor of 1st twisted pair 2nd conductor of 1st twisted pair 1st conductor of 2nd twisted pair 2nd conductor of 2nd twisted pair Data (-) Data (+) Data (-) Data (+) 4 3 Data In Cable Pinout 5 1 4 Male Conn 3 2 Female Conn Note: Refer to the USITT Recommended Practice for DMX512 guide for additional information r
Male Termination Connector A male XLR termination connector is required at the last luminaire (or "far end of the line") to prevent signal reflections. Signal reflections may cancel out the signal at certain line lengths, resulting in errors. The terminator is also necessary for software downloads and running tests on multiple luminaires. To construct your own connector, you will need the following components: + 5-pin, male XLR connector. + Two 1/4W 5% 120 ohm resistors.
INSTALLATION PROCEDURE Hanging the Luminaire The AutoPar wash luminaire can be hung horizontally or vertically from any structure designed to accommodate the load created by this moving luminaire. Two provided clamp mounts are used to attach truss hooks or other mounting hardware as required. A Mega-Claw truss hook is provided, however, other compatible truss hooks are available from manufacturers such as Grainger.
Installing in Truss: Step 1. Attach hardware and loop safety cable through mounting bracket slot (Figure 2-2). Step 2. Lift luminaire into mounting position (Figure 2-3). Step 3. Secure in place with truss hooks. Ensure truss hook hardware (e.g. wing bolt) is properly tightened and that luminaire is fully supported. Step 4. Attach safety cable around pipe as shown. Step 5. Connect power and data cables according to "Connecting Data and Power" on page 13.
Floor Mounting the Luminaire The luminaire enclosure is sufficient to stabilize the luminaire in a floor installation, provided that the mounting surface is flat and sturdy. Connecting Data and Power A maximum of 32 luminaires may be connected in any one DMX data link. Note: This maximum limit applies to the luminaire "daisy chain" only. Your system or console may require fewer luminaires on a single data link path. Consult your console documentation for more information. To connect power and data: Step 1.
POWER UP PROCEDURE Powering Up the Luminaire When AC power is applied, the luminaire will begin a calibration sequence which moves its pan, tilt, and lens rotation mechanisms. After calibration, the luminaire head will either stop at its "home" position (which positions the pan axis at mid-rotation and the head parallel to the yoke with the lens pointing away from the luminaire upper enclosure) or move to its current DMX-defined position if DMX512 data is present.
Programming a Starting Address The address setting for DMX512 systems is programmed at the Menu Display (refer to "Menu System" on page 18 for more detailed instructions). The luminaire retains its DMX512 address even if power is removed. Note: Refer to your console operating instructions for specific information regarding its addressing requirements. Program a DMX512 starting address: Step 1. Press [Enter] to access top level functions. Step 2. Press [Up] / [Down] arrows to scroll to Dmx menu.
Notes 16 AUTOPAR® WASH LUMINAIRE USER MANUAL
3. OPERATION This chapter contains instructions for using the Menu Display system and controlling the luminaire by DMX512.
MENU SYSTEM Overview The menu system is a programmable set of commands used to configure, address, and report status information at the Menu Display. The system is controlled by four buttons as shown in Figure 3-1.
Menu Functions The following is a graphic representation of the menu system. Fixture, Dmx, Lamp and Test are top level functions which have a series of sub-functions associated with each.
DMX512 OPERATION Channel Mapping These tables assume a DMX512 start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in sequence.
Control Channel Functions Control channel functions allow special actions such as reset, douse and start. These must be executed with zero time transition or with console timing disabled. Discrete values must be used; not manual controls such as faders or encoders (see chart below for values). Reset - resets all luminaire mechanisms. Douse - turns lamp off. Start - strikes lamp. DMX Value Action 85 Reset 168 Douse 252 Start To use control channel functions: Step 1. Select an action to be sent.
LUMINAIRE TIMING Timing Channel Information Timing channel control allows for smoother transition and movement of the luminaire mechanisms. In this case, timing channels are provided for focus (pan/tilt) and beam. Types of timing control: + Timing Control Channel: the luminaire uses its timing channel value to calculate a smooth, continuous movement for a given time and transition.
Timing channels can be set in either % or 0-255 (DMX) modes, with the following values assigned: Table 3-1: DMX Mapping (Continued) % Value Table 3-1: DMX Mapping % Value 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 DMX = Seconds 0 Full Speed 1 0.2 2 0.4 3 0.6 4 0.8 5 1 6 1.2 7 1.4 8 1.6 9 1.8 10 2 11 2.2 12 2.4 13 2.6 14 2.8 15 3 16 3.2 17 3.4 18 3.6 19 3.8 20 4 21 4.2 22 4.4 23 4.6 24 4.8 25 5 26 5.2 27 5.4 28 5.6 29 5.8 30 6 31 6.
Table 3-1: DMX Mapping (Continued) % Value DMX = Seconds 81 32 82 83 23 33 84 23 85 23 86 24 87 24 88 25 89 90 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 24 Table 3-1: DMX Mapping (Continued) DMX = Seconds 22 123 38 22 124 39 125 39 126 39 127 40 50 128 40 129 41 51 130 41 25 131 41 25 132 42 133 42 134 43 135 43 136 43 91 26 92 26 93 27 94 27 95 27 96 28 97 28 98 29 % Value 49 52 53 54 55 137 44 138 44 139 45 140 45
Table 3-1: DMX Mapping (Continued) % Value 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 DMX = Seconds 165 Table 3-1: DMX Mapping (Continued) % Value DMX = Seconds 55 207 130 166 55 208 140 167 56 209 140 168 56 210 140 169 56 211 150 170 57 83 212 150 171 57 213 160 172 58 84 214 160 173 58 215 160 174 58 216 170 175 59 217 170 176 59 218 180 177 59 219 180 178 60 220 180 179 60 180 65 181 65 182 65 183 184 185 75 186
Table 3-1: DMX Mapping (Continued) % Value 98 99 100 26 DMX = Seconds 249 300 250 300 251 310 252 310 253 310 254 310 255 Follows Cue Data AUTOPAR® WASH LUMINAIRE USER MANUAL
4. TROUBLESHOOTING AND MAINTENANCE This chapter provides a basic troubleshooting guide, along with procedures for extended care of the luminaire.
TROUBLESHOOTING Error Messages After calibration, the Menu Display will cycle through any applicable error message(s), one a time until the end of the list is reached. To review the error messages again, it will be necessary to access them using the Status function. The following table provides all possible error messages. These errors can be reported for each mechanism (Pan, Tilt, or Beam), except Enc Fail which does not apply to the Beam mechanism.
Troubleshooting Guide The following table provides a list of common failures and possible solutions. Symptom Message Solution(s) Refer to... Ensure power cable is properly connected to Neutrik input connector. No power to luminaire. page 13 n/a Ensure power is switched on at source (mains, disconnect box, etc.) No DMX512 control. Ensure data cable is connected to DMX In connector. page 13 Ensure DMX512 address setting is correct. page 15 No Comm Ensure data cables are correctly configured.
ROUTINE MAINTENANCE Replacing Lamp Parts: 71.2566.0700.0 LAMP, MSR 700W Tools: #2 Phillips Screwdriver WARNING: Remove power from luminaire before performing any maintenance procedures. CAUTION: Wear cotton gloves or other covering while installing lamp. Touching lamp glass with bare fingers will leave oil and may cause the lamp to explode or reduce lamp life. If touched, use alcohol and cotton cloth to thoroughly clean glass portion of lamp. To replace lamp: Step 1.
Aligning Lamp After a new lamp is installed, it will be necessary to align the lamp to optimize the beam. Screws located at the luminaire’s backcap allow for adjustment. Tools: #2 Phillips screwdriver Light meter To align lamp: Step 1. Remove power from luminaire. Step 2. Remove front lens (refer to "Replacing Front Lens" on page 32). Step 3. At backcap, using only top two adjustment screws (as shown in Figure 4-2), align lamp so that it is centered within the reflector hole.
Replacing Front Lens The luminaire includes four different front lens which can be swapped as needed. Parts: LENS, VERY NARROW LENS, NARROW LENS, 8-ROW LENTICULAR LENS, 12-ROW LENTICULAR Tools: none WARNING: Remove power from luminaire before performing any maintenance procedures. To replace Front Lens: Step 1. Remove power from luminaire. Step 2. At securing ring, squeeze flanges and remove (Figure 4-3). Step 3. Remove Front Lens. Step 4.
Installing a Color Gel Color gels can be installed in the gel frame located at the front of the head assembly. Tools: none To install/replace a color gel: Step 1. At front of luminaire, press latch to release gel frame as shown (Figure 4-4). Step 2. Remove gel frame from luminaire. Step 3. Install color gel in frame. Step 4. Re-install gel frame in luminaire and close latch.
Cleaning the Luminaire Tools: Window cleaner (commercial grade) Clean, lint-free cloth Vacuum cleaner with brush nozzle To clean the outside of the luminaire: WARNING: Remove power from luminaire before performing any maintenance procedures. Step 1. Remove power from luminaire. Step 2. Using vacuum cleaner with brush nozzle, gently clean dust from external components. Step 3. Apply window cleaner sparingly to clean, lint-free cloth. Step 4. Wipe outside surface of luminaire with cloth.
A.
AutoPar Wash Luminaire Description SOURCE: Philips MSR700 1CT 700W arc lamp Color Temp: 5600°K CRI: 85 BALLAST: Integrated electronic ballast with universal input and power factor correction. REFLECTOR: Modified parabolic, multifaceted reflector finished with a metal cold mirror dichroic coating. UV FILTER: Internal coated filter. Rejects greater than 99% of ultra-violet radiation.
4.80" (122 mm) 10.12" (257 mm) 11.38" (289 mm) Photometric Data AutoPar Luminaire with MSR700 Lamp LENS CANDELA (cd) ** BEAM ANGLE (degrees) BEAM (Tn) * FIELD ANGLE (degrees) FIELD (Tn) * VNSP 1,625,000 5° 0.087 14° 0.246 NSP 1,155,000 7.5° 0.131 15° 0.263 8-Row Horiz 360,000 18° 0.317 31° 0.555 8-Row Vert 360,000 12° 0.210 23° 0.407 12-Row Horiz 140,000 31° 0.555 50° 0.933 12-Row Vert 140,000 21° 0.371 33° 0.
Notes 38 AUTOPAR® WASH LUMINAIRE USER MANUAL
AutoPar® Wash Luminaire User Manual Version as of: November 8, 2010 PRG part number: 02.9802.0001.
Production Resource Group Dallas Office 8617 Ambassador Row, Suite 120 Dallas, Texas 75247 www.prg.