Mobility Aid - Wheelchair/Scooter Lift User Manual

18 www.pridemobility.com Jazzy 1103 Ultra
III. YOUR POWER CHAIR
Figure 6. The Jazzy 1103 Ultra Power Base
MOTOR/BRAKE ASSEMBLY
ARTICULATING BEAM
REAR SHROUD FASTENER
REAR TRAPEZE BAR
ELECTRICAL COMPONENTS
The electrical components are located on the power base. The main circuit breaker is located on the front of the battery
tray. The charger inhibit and motor connectors are located on the power pod, inside the power base. See figure 7.
Main Circuit Breaker: The main circuit breaker is a safety feature built into your power chair. When the batteries and the
motors are heavily strained (e.g., from excessive loads), the main circuit breaker trips to prevent damage to the motors and
the electronics. If the circuit trips, allow your power chair to “rest” for approximately one minute. Next, push in the circuit
breaker button, turn on the controller, and continue normal operation. If the main circuit breaker continues to trip repeat-
edly, contact your authorised Pride Dealer.
RETAINING CLIPS
MANUAL FREEWHEEL LEVER
FRONT TRAPEZE BAR