• THANK YOU Thank you for choosing this innovative Pridiom dehumidifier. This instruction manual describes the many benefits and advanced features that this unique product has to offer. • • • • Children should be supervised to ensure that they do not play with the appliance. Do not clean the dehumidifier by spraying it or immersing it in water. Do not insert any object into the opening of the dehumidifier. Disconnect from the mains before cleaning the unit or any of its components.
• THANK YOU Thank you for choosing this innovative Pridiom dehumidifier. This instruction manual describes the many benefits and advanced features that this unique product has to offer. • • • • Children should be supervised to ensure that they do not play with the appliance. Do not clean the dehumidifier by spraying it or immersing it in water. Do not insert any object into the opening of the dehumidifier. Disconnect from the mains before cleaning the unit or any of its components.
HOW IT WORKS DESICCANT ROTOR Your Pridiom Desiccant dehumidifier removes moisture using a continuously rotating moisture absorbing wheel/rotor (This ‘Desiccant Rotor’ is literally a ‘honeycomb’ of extremely hygroscopic membranes). A highly efficient yet low noise fan draws air into the unit (Process Air) and forces it through a portion of the absorbent rotor.
HOW IT WORKS DESICCANT ROTOR Your Pridiom Desiccant dehumidifier removes moisture using a continuously rotating moisture absorbing wheel/rotor (This ‘Desiccant Rotor’ is literally a ‘honeycomb’ of extremely hygroscopic membranes). A highly efficient yet low noise fan draws air into the unit (Process Air) and forces it through a portion of the absorbent rotor.
POSITIONING OPERATION The PGD970DES is designed only for indoor use however, it can be placed either inside or outside the room needing to be dried. Internal Positioning: When positioning the unit inside the room, place centrally, ensuring inlet and outlet ducts are clear of obstruction. If required, ducts can be connected to the outlet and/or inlet to direct the drying to specific areas. The Wet-Air-Out and Regen-Air-In MUST be ducted to and from outside the room.
POSITIONING OPERATION The PGD970DES is designed only for indoor use however, it can be placed either inside or outside the room needing to be dried. Internal Positioning: When positioning the unit inside the room, place centrally, ensuring inlet and outlet ducts are clear of obstruction. If required, ducts can be connected to the outlet and/or inlet to direct the drying to specific areas. The Wet-Air-Out and Regen-Air-In MUST be ducted to and from outside the room.
TECHNICAL DATA PGD970DES 74 Pt/Day Air Flow (Process) 14125 ft3/hr Air Flow (Regen) 4414 ft3/hr Voltage 120 V Current @ 80°F 12.5 A Frequency 60 Hz Power @ 80°F 1.5kW Phase 1ph Dimensions (in) 22.04 x 13.85 x 13.58 Weight (NET) 43.6 lbs Weight (GROSS) 50.7 lbs Operating Temperature -4°F – 104°F OUTLET DUCT 4.92 in REGEN AIR INLET DUCT 3.15 in 22.04" Disposal This marking indicates that this product should not be disposed with other household wastes.
TECHNICAL DATA PGD970DES 35 l /day Air Flow (Process) 14125 ft3/hr Air Flow (Regen) 4414 ft3/hr Voltage 120 V Current @ 80°F 12.5 A Frequency 60 Hz Power @ 80°F 1.5kW Phase 1ph Dimensions (in) 22.04 x 13.85 x 13.58 Weight (NET) 43.6 lbs Weight (GROSS) 50.7 lbs Operating Temperature -4°F – 104°F OUTLET DUCT 4.92 in REGEN AIR INLET DUCT 3.15 in 22.04" Disposal This marking indicates that this product should not be disposed with other household wastes.
MAINTENANCE ATTENTION: • Maintenance should only be carried out by qualified personnel • Unit should be disconnected from mains before removing covers • If unit has just been running, heater bank may still be hot Desiccant Rotor: The desiccant rotor is maintenance free however, if it becomes blocked with dust (e.g. if it has been running without inlet air filter) it can cleaned by vacuum cleaner or low pressure compressed air.
MAINTENANCE TROUBLE SHOOTING ATTENTION: • Maintenance should only be carried out by qualified personnel • Unit should be disconnected from mains before removing covers • If unit has just been running, heater bank may still be hot Desiccant Rotor: The desiccant rotor is maintenance free however, if it becomes blocked with dust (e.g. if it has been running without inlet air filter) it can cleaned by vacuum cleaner or low pressure compressed air.
SPARE PARTS WIRING DIAGRAM Description Part No.
SPARE PARTS WIRING DIAGRAM Description Part No.
SPARE PARTS Description Part No.
SPARE PARTS Description Part No.
201.266.6775 info@pridiom.com Englewood, NJ 07631 www.pridiom.