Specification

ID Part No. Description ID Part No. Description
1 See Below Stem Assembly, Contains: 1, 5, 6 P-231-0420 Stem for 20” C-434/C-534 Hydrant, 22
1
/
2
” OAL
P-231-04CC Stem for CC C-434/C-534 Hydrant, 5
1
/
4
” OAL P-231-0422 Stem for 22” C-434/C-534 Hydrant, 24
1
/
2
” OAL
P-231-0404 Stem for 4” C-434/C-534 Hydrant, 6
1
/
2
” OAL P-231-0424 Stem for 24” C-434/C-534 Hydrant, 26
1
/
2
” OAL
P-231-0406 Stem for 6 “ C-434/C-534 Hydrant, 8
1
/
2
” OAL 2 C-108KT-808 Loose Key on Lanyard
P-231-0408 Stem for 8” C-434/C-534 Hydrant, 10
1
/
2
” OAL 3 C-434KT-903 Stem Packing and Washer Kit
P-231-0410 Stem for 10” C-434/C-534 Hydrant, 12
1
/
2
” OAL 4 C-434KT-906 Vacuum Breaker Repair Kit
P-231-0412 Stem for 12” C-434/C-534 Hydrant, 14
1
/
2
” OAL 5 C-434KT-902 Stopper and Pin Kit (with tool and o-ring)
P-231-0414 Stem for 14” C-434/C-534 Hydrant, 16
1
/
2
” OAL 6 300-6003 Valve Stem Cap for C-534
P-231-0416 Stem for 16” C-434/C-534 Hydrant, 18
1
/
2
” OAL 7 C-534KT-804 Handle Conversion Kit to C-434
P-231-0418 Stem for 18” C-434/C-534 Hydrant, 20
1
/
2
” OAL C-534KT-907 Overhaul Kit for C-534, Contains: 2, 3, 4, 5, 6
4515 East 139th Street
Grandview, MO 64030
(800) 362-9055
Fax (800) 362-1463
www.PRIER.com
Replacement Parts & Stems
Rough-In Dimensions
1
5
3
4
7
6
2
**For the old style C-534 Series wall hydrant stems, see C-534 Series retired style spec sheet at www.PRIER.com.
Furnish and install freezeless model C-534 Commercial Wall Hydrant as manufactured by PRIER Products, Inc. Hydrant shall have automatic
draining capabilities with integral ASSE 1052 approved double check vacuum breaker/backow preventor. Hydrant shall have 3/4” hose con-
nection with freezeless water ow and self-draining functions. After hydrant is turned in the “off” position, hydrant must be capable of draining
even with the hose attached and under pressure without sprayback. Hydrant shall be constructed of all non-ferrous materials with EPDM sealing
mechanisms. Hydrant body must be satin nickel plated. For stability of operation, hydrant stem shall be secured at the seat end with ACME type
threads and at the handle end with the packing nut. Lockshield must be long enough to ensure operation only with the included operating key.
Hydrant must be installed through a 1 1/8” diameter hole without any custom brick cutting. Hydrant body shall incorporate proper drainage pitch
to ensure proper drainage. Operating Key is to be furnished with each hydrant. Hydrant insertion length to be * inches. *Close coupled to 24”
in 2” increments.
Optional: Furnish and install ush-mount hydrant box for each valve. Hydrant box shall be manufactured of stainless steel. Box may be installed
separately and hydrant be insertable and removable from front of the box. Access to the hydrant box shall be provided by the same operating
key as the valve.
Specs
5
*When assembling the vacuum breaker, ensure the dome is
facing out on the check spider and the step is facing out on the
silicone washer.
Hydrant Length 3/4”
2 5/8”
6 1/4”
5 7/16”
3 3/4”
2 1/32”
Hydrant Length 2 1/4”
3/4”