Installation Guide

INSTALLATION MANUAL
Congratulations on purchasing the Broadway London 12 Room Kit from Primacoustic.
The London 12 is an package of easy to install acoustic panels that will effectively absorb
a broad bandwidth of frequencies and look great for years to come. Because Broadway
panels are also Class-1 fi re rated, they are ideally suited to provide effective acoustic control
in applications as diverse as home-theatre, practice rooms, houses of worship, offi ces,
call centers and broadcast studios. Please take a few minutes to read through this install
manual. It includes a list of parts as well as step by step mounting instructions. Please refer
to www.primacoustic.com for various placement options, benefi ts, and general room acoustic
information. Should you have any questions or comments, we invite you to send us an email
at: info@primacoustic.com
Primacoustic is a division of Radial Engineering Ltd. 1588 Kebet Way, Port Coquitlam, BC Canada V3C 5M5
Tel: (604) 942-1001 • Fax (604) 942-1010 • info@primacoustic.com. Specifi cations and appearances subject to change
without notice.
Primacoustic London 12 manual rev.001 / Part #: R870-2028-00 Copyright © 2011, all rights reserved.
WARRANTY
Please inspect panels immediately after purchase and before mounting. Primacoustic Broadway acoustic panels are guaranteed to be free of manufacturing defects for a period of thirty (30) days after purchase. In the unlikely event that a
defect is uncovered, please call 604-942-1001 to obtain an RA number (Return Authorization number) from Primacoustic before the thirty (30) day warranty period expires. Once you have obtained an RA number you must return the product,
freight prepaid, within fi fteen (15) days after the date the RA number is issued. Please return the product in the original packaging (or another, affording an equal degree of protection) with all of the following: (1) RA number clearly marked on
the returned package; (2) a receipt or bill of sale showing proof of purchase from an authorized retail seller; and (3) a written note describing the defect and including your name, address, telephone number and the applicable RA number. You
are solely responsible for all shipping and insurance costs for returning the product to Primacoustic, and you will not be reimbursed or compensate for any loss or damage incurred during return shipping. Primacoustic will at its discretion repair
or replace the panel. Should the panel be no longer available, Primacoustic reserves the right to exchange this with a panel of similar performance and value. Due to different dye lots, Primacoustic cannot guarantee exact color match. This
Warranty shall solely extend to the original owner and is limited to manufacturing defects only and excludes damage due to improper installation, freight handling, wear and tear, abuse, misuse, misapplication, color fading or deterioration due
to prolonged exposure to ultra violet light, smoke, humidity or other environmental factors. It is understood that the use and suitability of Broadway is entirely the responsibility of the buyer or specifying engineer and as such, these parties agree
to hold Primacoustic, or its associated company, and/or offi cers, harmless from any responsibility whatsoever other than what is clearly outlined in this warranty.
TEST CLASS FLAME SPREAD SMOKE DENSITY
ASTM E 84-05 1 OR A 15 FSI 155 SD
CAN/UL-S102 1 OR A 15 FSC1 155 SD
Test data provided by Bodycote Materials Testing Inc. This method, designated as ASTM E 84-05, “Standard Method of
Test for Surface Burning Characteristics of Building Materials”, is used to measure and describe the response of materials,
products, or assemblies to heat and fl ame under controlled conditions, but does not by itself incorporate all factors required
for fi re-hazard or fi re-risk assessment of the materials, products, or assemblies under actual fi re condition. Broadway
panels have been tested to meet the most stringent ASTM and CSA testing requirements for the USA and Canada. For
international customers, please consult your local building authority for proper cross-compatibility specifi cations.
FIRE & BURN TESTING
SURFACE COVERAGE AREA
60 sq/ft (5.6 sq/m) total surface area of all panels
CORE MATERIAL
Formed, semi rigid inorganic glass fi bers; Density = 6.0 lbs. (2.72kg/m3) per cubic foot
FABRIC FACING
Acoustically transparent polyester; Color code: Black=00, Beige=03, Grey=08
• Bubble level
• Phillips #2 screw driver
• Power drill
BOX CONTENTS:
Before beginning assembly, please take a moment to
familiarize yourself with the box contents.
Ref.# (Qty.) Description:
(2) 24” x 48” x 2” Broadway Broadband panels.
Corner traps to reduce excessive bass and
absorb primary refl ections.
(8) 12” x 48” x 2” Broadway Control Columns.
Wall mounted to control primary refl ections.
(12) 12” x 12” x 1” Broadway Scatter Blocks.
Spaced to produce Soft Diffusion™ effect.
(28) Surface impaler mounting clips.
(8) Corner impaler mounting clips.
(1) Package of 100 wall anchors and screws.
(1) Drywall/masonry 1/4” drill bit.
SPECIFICATIONSTOOL REQUIRED
LONDON 12
ROOM KIT

Summary of content (4 pages)