Data Sheet

ENGINEERING DATA SHEET
Primacoustic is a division of Radial Engineering Ltd. • 1845 Kingsway Ave. Port Coquitlam BC V3C 1S9 • Tel: 604-942-1001 Fax: 604-942-1010
www.primacoustic.com • info@primacoustic.com • Primacoustic Engineering Data Sheet • Part #R870 2200 00 • Copyright © 2016 • Subject to change without notice.
The Primacoustic Saturna™ is a high performance acoustic bafe, designed
to be suspended perpendicular to tall ceilings. Particularly effective in large
open spaces where traditional wall mounted acoustic panels do not provide
enough absorption; the Saturna is perfect for demanding installations where
sound control and an attractive appearance are equally important. For
spaces with lower ceilings, the Saturna LP provides the same control without
sacricing ceiling height, while the smaller Mini ts even tighter spaces.
The Saturna is made from high-density (6 pcf/96kg/m
3
) glass wool, offering
superior absorption to low cost PVC or fabric alternatives. The Saturna is
available in black, beige or grey fabric or Absolute White™ paintable nish.
SATURNA
/ LP / MINI
SPECIFICATIONS:
ORDER NUMBER Z840-1215-XX LP: Z840-1220-XX Mini: Z840-1230-09
COLOR CODE Black=00, Beige=03, Grey=08, White=09 (Mini = White only)
DIMENSIONS Saturna: 24" (610mm) x 48" (1,219mm)
Saturna LP: 12" (305mm) x 48" (1,219mm)
Saturna Mini: 8" (200mm) x 36" (915mm)
THICKNESS 1.5" (38mm)
CORE MATERIAL Formed, semi-rigid inorganic glass bers, 6.0 lbs pcf (96 kg/m3)
WEIGHT TBA
FACING
Acoustically transparent polyester or paintable glass wool tissue micromesh
sealed with latex paint
MOUNTING Corkscrew™ anchors and SlipNot™ suspension cables included
RECYCLED CONTENT Up to 51%
LEED ELIGIBLE Yes
* Testing performed by Riverbank Acoustical Laboratories. The test method conform explicitly with
the requirements of the ASTM Standard Test Method for Sound Absorption and Sound Absorption
Coefcients by the Reverberation Room Method: ASTM C 423-02a and E795-05.
PANEL DEPTH 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz
1.5" (38mm) Depth 0.31 0.67 1.01 1.00 1.01 1.00
ABSORPTION CHARACTERISTICS:*
Sound absorption coefcient data
CONVENTION CENTER:
INDUSTRIAL PLANT
FIRE & BURN PERFORMANCE:
COUNTRY TEST STANDARD CLASSIFICATION
FABRIC WRAP
Canada CAN/ULC-S102-03 Class A/1
USA ASTM E84-09 Class A/1
Europe EN 13501-1 A2-s1, d0
Australia / New Zealand AS/NZS 1530.3 (I)0, (S)0, (H)0, (Sm)5
PAINTABLE
Canada CAN/ULC-S102-10 Class A/1
USA ASTM E84-11b Class A/1
Europe EN 13501-1 B-s2, d0
Australia / New Zealand AS/NZS 1530.3 (I)0, (S)0, (H)0, (Sm)3
100Hz
125Hz
160Hz
200Hz
250Hz
315Hz
400Hz
500Hz
630Hz
800Hz
1kHz
1.25kHz
1.6kHz
2kHz
2.5kHz
3.15kHz
4kHz
5kHz
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
FREQUENCY (Hz)
SOUND ABSORPTION COEFFICIENT
1.5" Panel
Surface Mounted

Summary of content (1 pages)