4.19. Sensor Temperature Control
The Sensor Temperature Control registers are shown below.
Since the PXG130S and PXG030S do not have a Perche element, the only item that can be used in the Sensor Temperature
Control register is the Sensor Temperature.
Sensor Temperature Control register list
Name Visibility Access
Values
Control Mode Beginner R/W
OFF
PID Control
Sensor Temperature Beginner R Sensor Temperature [℃]
Target Temperature Beginner R/W Target temperature for temperature control [℃]
The recommended set temperature for the Sensor is 15 ° C.
The Sensor temperature can be controlled to 15 ° C when the camera's ambient temperature is 35 ° C or less. If the ambient
temperature is higher than 35 ° C, the Sensor temperature cannot be guaranteed controlled to 15 ° C.
But even in that case, by setting the control mode to PID Control, the sensor temperature is kept lower than the ambient
temperature.
This camera is designed that the sensor cannot be heated by the Peltier element, so if the ambient temperature is low, the
sensor temperature cannot rise beyond the natural rise of internal temperature of the sensor and the camera.
4.20. AE&AGC Control
The AE&AGC Control registers are shown below.
AE&AGC Control register list
Name Visibility Access
Values
Control Mode Beginner R/W
OFF
Auto Gain
Auto Gain, Exposure
Auto Gain, Exposure, FR
Control Speed Beginner R/W
Fast
Medium
Slow
Current Brightness Beginner R 0~4095
Target Brightness Beginner R/W 0~4095
Auto Gain Max Beginner R/W 0~42dB
Auto Frame Rate Min Beginner R/W 12~(Frame rate max)
Auto Frame Rate Max Beginner R/W 12~(Frame rate max)
Area X Left Edge Beginner R/W 0~(Sensor width)
Area X Right Edge Beginner R/W 0~(Sensor width)
Area Y Upper Edge Beginner R/W 0~(Sensor height)
Area Y Bottom Edge Beginner R/W 0~(Sensor height)